Setting Left and Right Scan Limits

Scan Limits allow you to set left and right boundaries for use with the Auto Scan, Frame Scan, and
Random Scan functions. If the scan limits are not set, the dome pans continuously to the right when
these functions are activated.

I M P O R T A N T

You must program the Left Scan Limit setting before programming the Right Scan
Limit setting. This procedure erases any previously programmed Right Scan Limit
setting.

To program the Scan Limits:

1. Select the camera number assigned to the SpeedDome Ultra VII dome.

2. Use the pan/tilt control to position the dome’s pointing direction to the Left Scan Limit.

3. Enter

Set Preset 92 to save the setting.

4. Position the dome’s pointing direction to Right Scan Limit.

5. Enter

Set Preset 93 to save the setting.

Activating Auto Scan

Auto Scan allows the dome to continuously pan between the left and right scan limit settings. When
reaching the right scan limit, the direction is automatically reversed. If no scan limit settings are
programmed, the dome pans to the right continuously.

To activate the Auto Scan:

1. Select the camera number assigned to the dome.

2. Enter

Go To Preset 99.

The Auto Scan runs until stopped by selecting the camera and entering Call Preset 96.

Note:

Entering a pan/tilt or lens command also stops the scan.

Pelco Coaxitron and “P” Protocols Command Summary