Sloped Drain Pan

drainage system

GeneralAire HRV/ERV units

are equipped with an easy-

access sloped drain pan.

Excess condensation that

might accumulate inside the unit

migrate to the centre of the drain pan
to be evacuated.

8. Condensation Drain Line

Insert the threaded drain adapter thru the bottom of the HRV or ERV and hand tighten the
plastic nut supplied with the drain kit.

Install the condensate line (10 feet included in drain kit). Insert condensate tubing by pushing
clear plastic line over drain adapter. Make condensate trap by looping the clear plastic tubing.
This procedure is to avoid foul odor to enter the HRV or ERV.

figure 8.1 Hand screw the drain adapter

figure 8.2 Insert condensate line.

figure 8.3 Make a loop in condensate line.

figure 8.4 Use a condensate pump if
you don’t have access to the floor drain.