RDA-CKM Dual Choke Module

The RDA-CKM Dual Choke Module is used for debuzzing, lamp noise
reduction, and to correct minor common neutral interactions. This unit con-
sists of dual 350 µS rise time chokes. It occupies only one enclosure space
and is useful with the RDD-DM series of integrated dimmer modules. The
module's 120 and 240-277 VAC ratings are UL and C-UL approved.

RDA-CKM UL and C-UL Ratings:

Input:

•

120 VAC, 50/60 Hz, 2400 W

•

240-277 VAC, 50/60 Hz, 2400 W

Specifications:

•

Dimensions (HW): 10.0" x 2.75" (254.00 mm x 69.85 mm)

•

Use wires rated at 75°C (167°F)

•

Torque terminals to 7 in-lbs (0.8 N/M)

•

Max. wire size: 10 AWG (4 mm²)

•

Wire stripping length: 0.28" (7 mm)

•

Weight: 6.5 lbs (2.95 kg)

•

BTU/hr: 300

Suggested Loads:

•

Incandescent

•

Low-voltage

•

Neon, cold-cathode

Caution Pre-Installation Notes:

•

All Class 1 wiring must be connected to proper terminals.

•

All control wiring must be connected to proper terminals.

•

Disconnect power while installing or connecting the unit.

•

Keep top and bottom air vents clear at all times.

•

Test loads for shorts before connecting.

•

Use low-voltage wires with a 300 volt rating or greater.

•

Use field-installed copper conductors.

•

Run all low-voltage and control wires away from heat producing parts

of the dimmer.

•

Each dimming circuit must have a separate neutral connection.

•

All electrical ratings are for continuous duty.

•

For indoor use only.

•

AC lighting loads only.

FIG. 1 RDA-CKM

Mounting points

Mounting points

Line In (hot)

Load out

350 µS Choke

High-voltage
connections

Advertising