Installing a new Compact Flash Card

To install the new compact fl ash card, you will need a Phillips screw-

driver, the compact fl ash card and power for the analyzer. You can

use a vehicle’s battery, or the optional AC power supply.

Step 1

Remove the 4 screws holding the back panel in place. Then remove

the back panel.

Step 2

Locate the compact fl ash card and remove it. Install the new com-

pact fl ash card. It will only go in one way, and takes gentle pressure

to seat the card.

Step 3

Reattach the back panel and apply power to the labscope.

Step 4

Press the Menu button to bring up the selection menu

Step 5

Press the Help and Hold buttons at the same time. This will bring up

a hidden menu.

Step 6

Use the arrow keys to select Reprogram DSP. Press the NEXT but-

ton. The screen should dramatically change contrast to the point

you cannot read what is on the screen. If the screen looks the same,

press the NEXT button again. Wait a few minutes until the DSP is

reprogrammed and the labscope reboots.

Step 7

Perform Step 4 and 5 again to get to the hidden menu. Use the ar-

row keys to select Restore Factory Defaults. Press the NEXT button.

This will take about a minute. When the analyzer is fi nished, it will

beep. You are done reprogramming the labscope.