Trouble shooting guide cont’d – Hydrotech 5600 & 2510 Valve Automatic Iron & Sulfur Filter Operation Manual User Manual

Page 14

Advertising
background image

12

Trouble Shooting Guide Cont’d

PROBLEM

CAUSE

CORRECTION

7. Iron filter fails to draw

A. Drain line flow control is

A. Clean drain line flow control

chemical

plugged

B. Injectors and/or screen plugged

B. Clean or replace injectors and/or screen

C. Line pressure is too low

C. Maintain line pressure at 20 psi (139.9

kPa) minimum

D. Internal control leak

D. Change seals and spacers and/or piston

assembly

8. Drain flows continuously

A. Foreign material in control

A. Remove piston assembly and inspect

bore, remove foreign material and check
control in various regeneration positions

B. Internal control leak

B. Change seals and spacers and/or piston

assembly

C. Control valve jammed in brine

C. Replace piston and seals and spacers

or backwash position

(and drive motor if necessary)

D. Timer motor stopped or jammed D. Replace timer motor

9. Pink color (potassium

A. Poor water pressure or

A. Be sure pump is set at 20 psi (139.9

permanganate) present

insufficient pump capacity

kPa) minimum and is capable of

after regeneration; medicinal

producing 5 - 12 USGPM according

water taste

to filter size

B. Chemical in water supply

B. Decrease frequency of regeneration