Manual regeneration cycle, Potassium permanganate feeder – Hydrotech 5600 & 2510 Valve Automatic Iron & Sulfur Filter Operation Manual User Manual

Page 8

Advertising
background image

6

Manual Regeneration Cycle

If you run out of filtered water because of inadequate regeneration frequency, inadequate reserve capacity, power failure
or unusually high water usage, you can initiate a manual regeneration simply by pressing the extra cycle button. The
filter will now automatically complete a regeneration cycle and return to service. If possible, avoid water use during the
regeneration cycle.

Once you have set your filter you may experience frequent loss of water pressure, you may have to increase the
frequency of regeneration by decreasing the number of gallons between regeneration.

Potassium Permanganate Feeder

The potassium permanganate feeder assembly incorporates a non-pressurized storage tank and innovative new grid
design along with a dependable float valve.

The attractive 10" x 16" black tank is made of touch blow-molded high density polyethylene. It has a potassium
permanganate capacity of 30 lbs. and a liquid capacity of 5 gallons.

The black injection molded cover is securely fastened with three stainless steel safety screws to prevent access by
children and pets. Also, the potassium chemical tank should be placed where it is free from possible upset or access by
children or pets.

Chemical warning label and drain caution label are affixed to unit.

The unique polypropylene grid pad refuses to allow even the finest grade of undissolved potassium permanganate to
pass through the grid. This permits efficient use of our assembly with all grades of potassium permanganate. Standard
grid platform height is 6". Additional heights are available - consult factory.