Operating instructions – Hydrotech 5600 & 2510 Valve Automatic Iron & Sulfur Filter Operation Manual User Manual

Page 6

Advertising
background image

4

Operating Instructions

Setting the Frequency of Automatic Regeneration

Setting the 24 Hour Timer

The 24 hour timer must correspond with the correct time of day to ensure proper cycling of your filter.

Disengage the drive gear by pressing and holding in the red button on the left side of the control.

Now turn the large dial until the actual time of day is at the time of day arrow at the bottom of the panel.

Release the red button and check for firm engagement at setting.

The correct time of day on the 24 hour clock has now been set.

Time of Automatic Regeneration

The time of automatic regeneration is factory set at 12:00 a.m.

The amount of iron, manganese and sulfur to be removed per day
must first be determined using the following calculations:

Number of people in the household

x 60 gallons of water per person
= Number of gallons of filtered water required per day

x ppm of iron in the water sample
= TOTAL AMOUNT OF IRON TO BE REMOVED PER DAY.

5600CC Model

2510CC Model