Contaminant reduction performance – Hydrotech 1240 Series ADVANCED REVERSE OSMOSIS WATER TREATMENT SYSTEMS User Manual

Page 4

Advertising
background image

II

CONTAMINANT REDUCTION PERFORMANCE

Hydrotech Performance as tested by an outside agency is shown below. Past test results may not be indicative of current performance
and your results may vary depending on conditions.

MODELS AND SYSTEM CONFIGURATIONS

Table 1

CONDITIONS FOR USE

Table 2

OPTIONS AND ACCESSORIES

MODEL

DESCRIPTION

STORAGE

TANk

# OF

VESSELS

STORAGE

TANk

CAPACITY

LITRES (GAL)

VESSEL 1

VESSEL 2 VESSEL 3

VESSEL 4

DAILY

PRODUCTION

RATE

2

L/DAY

(G/DAY)

EFFICIENCY

RATING

3

%

RECOVERY

RATING

4

% MONITOR

6

4VTFC09G-PB

Plastic/Metal

4

6.81 (1.8)

Sediment Filter

Carbon

Filter

TFC

1

Membrane

Carbon

Filter

15.5 (4.1)

12.8

35

Smartap®

Push

Button

4VTFC25G-PB

Plastic/Metal

4

7.19 (1.9)

Sediment Filter

Carbon

Filter

TFC

1

Membrane

Carbon

Filter

29.1 (7.7)

8.2

18

4VTFC50G-PB

Plastic/Metal

4

6.81 (1.8)

Sediment Filter

Carbon

Filter

TFC

1

Membrane

Carbon

Filter

34.44 (9.1)

4.8

16.7

4VTFC75G-PB

Plastic/Metal

4

7.19 (1.9)

Sediment Filter

Carbon

Filter

TFC

1

Membrane

Carbon

Filter

49.58 (13.1)

5.7

15.3

SOURCE WATER SUPPLY PROFILE

ChEMICAL PARAMETERS

MAx MG/L

Community/Private

Chlorinated/Non-Chlorinated

Hardness (CaCO3 )

<170 (10 gpg)

Feed Water Pressure(5)

242-690 kPa (35-100 psig)

Iron (Fe )

<0.1

Temperature

4°-38° C (40°-100° F)

Manganese (Mn)

<0.05

pH Range

3.0 - 11.0

Hydrogen Sulfide (H2S )

0.00

Maximum TDS Level

2000 mg/L

Residual Chlorine (Cl2)

<2.0

Turbidity**

<1.0 NTU

** Nephelometric Turbidity Unit

*** Silt Density Index: Value stated in SDI units.

Maximum SDI***

<4.0

NOTES:

1. TFC refers to reverse osmosis membranes constructed from a THIN FILM COMPOSITE

2. The daily production rate is the volume of product water produced by the system per day and is determined by testing in accordance with the procedure outlined

in NSF/ANSI Standard 58.

3. System’s Efficiency rating as verified by testing in accordance with NSF/ANSI standard 58. Efficiency rating means the percentage of the influent water to the system that is available to

the user as reverse osmosis treated water under operating conditions that approximate typical daily usage.

4. System’s Recovery rating as verified by testing in accordance with NSF/ANSI Standard 58. System’s Recovery rating means the percentage of the influent water to the membrane portion

of the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed.

5. PRESSURE REGULATOR IS RECOMMENDED FOR FEED WATER PRESSURES EXCEEDING 552 kPa (80 psig)

6. SMARTAP® PUSH BUTTON MONITOR. Indicator lights located on the module cover report system status.

PRODUCT WATER FAUCETS

BOOSTER PUMP

Faucets will be supplied as Air Gap.

A booster pump may be used if system pressure is below 242 kPa (35 psi).

Pump should be placed near RO Module and installed in feed water line just before it enters Module.