Inter-component connections, Figure 2: how to use quick-connect fittings, Plastic tubing – Hydrotech 1240 Series ADVANCED REVERSE OSMOSIS WATER TREATMENT SYSTEMS User Manual

Page 8: Quick-connect fittings

Advertising
background image

2

PERFORMANCE INDICATORS

OPTIONAL SMARTAP® WATER QUALITY MONITOR

WaterGroup’s 12403 Series Reverse Osmosis Systems incorporate a proven performance indicator. Our patented Smartap

®

Water Quality

Monitor uses dual probe LOGIC PULSE MEMORY technology to accurately indicate membrane performance. A split-second power pulse
compares feed water Total dissolved Solids (TdS) level with that of the product water. Then, by reversing the polarity of the electronic pulse,
the probes are cleaned and kept free of chemical plating. A nine-volt alkaline battery provides power to the Monitor. For optimum monitor
performance, the battery should be replaced each time system is sanitized.

NOTE: Monitor Troubleshooting indicators and Common Solutions are shown in Table 5 on Page 12.

Push Button Actuated Smartap® – 12403 Series

Pressing a test button located on the manifold cover activates monitor. When button is pressed, and momentarily held down, monitor
reports membrane status by illuminating a light located next to test button. A green light means system is operating normally. A yellow light
indicates system needs servicing (membrane may be depleted or fouled). While the button may be pressed at any time, the most accu-
rate readings are obtained when the system is making water for at least 10 minutes.

The customer can also contact the local dealer for water sampling service or kit.

INTER-COMPONENT CONNECTIONS

Connections between cold water supply line, ro Module, storage tank, product water faucet, and drain line are accomplished using plas-
tic tubing and push-together quick-connect type fittings.

PLASTIC TUBING

1. Cut tube ends square and straight. Do not deform tube (i.e.,

cause tube to compress its diameter so it is no longer round).

2. Make sure outer surface of tube is clear of marks or scratches for

a length equal to twice tube diameter. This allows “O” ring to
seat properly against tube.

3. Avoid sharp changes in direction when routing tubing. Sharp

turns cause tubing to flex and deform, which reduces its flow
capacity and may increase lateral stress on the fittings, causing
leakage.

QUICk-CONNECT FITTINGS

Fittings consist of two parts: a Body and a colored collet and sym-
bol. Collet color and symbol corresponds to tubing to be used at
that connection (Figure 2.A.).

1. To install a tube, push it through Collet until it seats firmly at bot-

tom of fitting (Figure 2.A and 2.B.).

2. To remove a tube, push and hold Collet against Body while pull-

ing tube out (Figure 2.C.).

Figure 2: How to Use Quick-Connect Fittings

A. Push tube through Collet into Body.

COLLET

BODy

B. Tube must seat firmly at bottom of fitting.

C. Push Collet against Body to release tube.

Advertising