ENGLISH

Trimmer A.C.T.

= Automatic closing time. Adjusts the wait time of the gate in the open position, also known as “pause time”;

at the end of this time, a closing movement is automatically activated. The “pause time” can be adjusted from 1 second to 120
seconds.

Trimmer PAR.OP.

= Partial opening. Adjusts the opening time of the gate. By pressing the partial opening button on 2-3P,

the gate will open for a set time between 2 and 15 seconds.

The automatic closing time will change in the following manner with this function:

- dip-switch 1 to ON «activated automatic closure» the closing time is set by adjusting the A.C.T. trimmer after partial ope-
ning;

- dip-switch 1 to OFF «deactivated automatic closure», with A.C.T. trimmer set to the minimum setting, automatic closure
counting does not start after partial opening; con trimmer del A.C.T. set to the maximum setting, the closing time is fi xed at 8

seconds after partial opening.

1 ON - Automatic closing - The automatic closing timer is automatically activated at the end of the opening cycle. The preset,

adjustable automatic closing time is automatically interrupted by the activation of any safety system, and is deactivated
after a total stop command or in case of power failure;

2 ON - Radio function command and/or “open-stop-close-stop” button (with radio-frequency card inserted).

2 OFF - Radio function command and/or “open-close-inversion” button (with radio-frequency card inserted).

3 ON - Radio function command “only open” (with radio-frequency card inserted).

4 ON - “Maintained Action” operations - Operation of the gate by keeping the pushbutton pressed for opening on 2-3, button

for closing on 2-4 (excluding the radio transmitter operations).

5 ON - “Pre-fl ashing during opening and closing” - After an opening or closing command, the fl ashing lamp connected to

W-E1 fl ashes for 5 seconds before beginning the manoeuvre.

6 ON - Obstacle detection - With the motor not running (gate closed, open or after a total stop command), this hinders any

movement if the safety devices (e.g. photoelectric cells) detect an obstacle.

7 OFF Re-opening during closure - If the photoelectric cells identify an obstacle while the bar is closing, they will reverse the

direction of movement until the gate is completely open; insert safety device on the clamp (2-C1); if not used, select
the dip in ON.

8 OFF - Partial stop - The gate stops if in motion with resulting order of automatic closing, insert safety device on the clamp

(2-C3); if not used, set the dip to ON.

9 OFF - Total stop - This function stops the gate, with the resulting exclusion of an automatic closing cycle; to resume movement,

the pushbuttons or transmitters must be used. Insert the safety device on (1-2); if not used, set the dip to ON.

10 OFF- If unused, leave the dip-switch in the “OFF” position

ON
OFF

/.





       

6.7 Adjustments

6.6 unction selections (dip-switch)