PRESET Keys Lock and Unlock

PRESET keys A through H can be locked in order to

prevent storing, altering or erasing a program.
To lock the PRESET keys, press and hold the "I" key until

the oven beeps. Release the “I” key. The green indicator

on the "I" key will illuminate. Oven PRESET keys A

through H are now locked.
Note: Only the oven PRESET keys A through H are

affected by this lock-out in order to also allow the

oven to be used with the unprogrammed Cook,

Probe, or Hold modes.

To unlock the PRESET Keys, press and hold the

CANCEL key along with the "I" key until you hear a

brief beep. Release all keys. The green indicator on the

"I" key will extinguish. The oven preset keys are now

unlocked.

Fahrenheit or Celsius Selection

With the control in the off mode,

press and hold the UP ARROW key until the

display toggles between Fahrenheit and

Celsius. After each change the button must

be released. The display must clear before

the procedure can be repeated.

Control Panel Lock and Unlock

The control panel can be locked at any time in order to

prevent inadvertent or accidental setting changes.
To lock the control panel, press and hold the UP ARROW

key and then press the ON/OFF key.

You will hear a brief beep and the panel lock

indicator will illuminate. Release all keys. The oven's

control panel is now locked.
Note: The control panel is now fully locked

with the exception of the ON/OFF key and

ARROW keys. You will be unable to turn the oven

control off at this point.

To unlock the control panel, press and hold the DOWN

ARROW key and then press the ON/OFF key. You will

hear two brief beeps and the panel lock indicator will

extinguish. Release all keys. The panel is now unlocked

and ready for normal use.

Beeper Volume Selection

With the control in the off mode,

press and hold the D

OWN

A

RROW

key

until the display shows one of the 4

volume levels (0 being

OFF

or the lowest,

and 3 being the highest). After each

change, the button must be released and

the display must clear before the

procedure can be repeated to select a

different volume level.