Error
Code

Description/Results

Possible Cause
Service Required

E-10

Air Sensor Fault (shorted)

Ino p erative Oven

Air sensor is shorted.

Air sensor defective? See following page for air sensor test.

E-11

Air Sensor Fault (open)

Ino p erative Oven

Air sensor is open or connection failure.

Air sensor defective? See following page for air sensor test.

E-20

Product Probe Fault (shorted)

Oven w ill co o k in tim e o nly

Product probe is shorted

Probe defective? See following page for probe sensor test.

E-21

Product Probe Fault (open)

Oven w ill co o k in tim e o nly

Product Probe is open or connection failure.

Probe defective? See following page for probe sensor test.

E-30

Under temperature

Oven will not reach set temperature

Oven door closed? Door gasket need replacement? Preheat skipped?

Oven overloaded or has frozen product? Defective air sensor or probe?

Defective solid state relay? Bad wire connections or open heating cable?

Is the high limit switch tripped? If none of the above, call service.

E-31

Over temperature

Oven w ill shut d o w n

Shorted cable? Defective solid state relay? Defective air sensor?

If none of the above, call service.

E-60

Real time clock error

Ino p erative Oven

Control must be replaced.

This error also is displayed if the unit has been unplugged for more than 30

days. If this is the case the unit should be plugged in with the circuit breaker

on and the unit displaying the E-60 on the front panel for more than 30

minutes. Once this has been accomplished the circuit breaker should be

turned to off or the unit unplugged for about 10 seconds after which the unit

should be turned on again. This may have to be repeated.

E-70

Configuration connector error

Ino p erative Oven

Check control connections for loose wires. If none, control must be replaced.

E-78

Voltage low

Ino p erative Oven

If 125 VAC unit, voltage is below 90 VAC. Correct.

If 208-240 VAC voltage is below 190 VAC. Correct.

E-79

Voltage high

Ino p erative Oven

If 125 VAC unit, voltage is over 130 VAC. Correct.

If 208-240 VAC, voltage is over 250 VAC. Correct.

E-80

EEPROM - Function data error

Ino p erative Oven

Contact Service.

E-82

EEPROM - Calibration data error

Ino p erative Oven

Contact Service.

E-84

EEPROM - Unit ID error

Ino p erative Oven

Contact Service.

E-86

EEPROM - Preset data error

Ino p erative Oven

Contact Service.

D A N G E R

DISCONNECT UNIT FROM

POWER SOURCE BEFORE

CLEANING OR SERVICING.

C A U T I O N

THIS SECTION IS PROVIDED FOR THE ASSISTANCE

OF QUALIFIED SERVICE TECHNICIANS ONLY AND

IS NOT INTENDED FOR USE BY UNTRAINED OR

UNAUTHORIZED SERVICE PERSONNEL.

TH/III

INSTALLATION

/

OPERATION

/

SERVICE MANUAL

PG

. 21

Advertising