Select a location for the

BaseStation and/or Remote Transceiver

1

3

System range and performance may be greatly reduced if antennas are

blocked or obstructed.

●

Always operate the system with antenna attached, locate as high as
possible and away from all obstructions (especially metal).

●

Never use antenna on the back of the BaseStation when the BaseStation
is in a rack

●

When using the Whip (omni-directional) antenna, always locate it as close
as possible to the center of the coverage area.

●

When using a directional antenna, always aim it in the same general
direction.

●

When remotely locating antenna, use only high quality 50 ohm, low loss,
RF cable (30 ft max).

●

Remote antenna location of up to 1500 ft using standard CAT-5 wiring
may be achieved using the optional Tempest Remote Transceiver.

» This must be a point to point connection
» Plug your Transceiver into the BaseStation prior to powering ON the

BaseStation

●

Connect the AC power cord to the BaseStation and to the AC wall outlet.

●

Turn the BaseStation on via the front panel ON/OFF switch.

●

The first time you power up the BaseStation, you will be prompted
to “select an authorized band for your location”.

●

There are seven RF bands that use different parts of the 2.4GHz
spectrum.

●

Scroll to an appropriate band for your location and press Enter to
select.

●

Press MENU to return to the operational screen.

Band 1 is appropriate for most, but not all, locations worldwide (US is

band 1). Some countries require that you use a limited portion of the

2.4GHz band. It is the user’s responsibility to ensure that you select a

band that is permitted for use in your location.

Power ON the BaseStation

Selecting the RF band

MHz

Band Start

End

Wide Avoid 802.11b/g

1

2400 2480

80

None

2

2400 2450

50

11

3

2423 2473

50

1

4

2431 2480

49

1,2

5

2400 2428

28

7,8,9,10,11

6

2423 2450

27

1,11

7

2453 2480

27

1,2,3,4,5,6,7

4

From the front of the BaseStation, follow the steps below :
1. Press MENU (Main Menu)
2. Press 1 (BaseStation Settings).
3. Scroll to 7 (Tech Menu) and press ENTER. A Tech Menu warning

message will appear - Press ENTER to proceed.

4. Press ENTER or 1 (Radio Configuration).
5. Press ENTER or 1 (Network Number) and select a network other than

zero and press ENTER to save setting.

» If you have multiple BaseStations, ensure that you select a different

Network Number for each BaseStation.

» Collocated BaseStations should be in the same Network Number

Group.

6. Press MENU to return to previous menu; press 2 (Lockout Key) and

select a lockout key other than 255 and press ENTER to save setting.

7. Press MENU repeatedly until you get back to the Operational screen.
8. Power the BaseStation OFF; wait 10 seconds and power the BaseStation

ON again.

Changing the Default RF

Configuration

9

9

Tempest 2400 operates in the 2400 to 2483 MHz frequency
spectrum and should never be synced with 900 MHz models.

9

9

Tempest® BaseStations and BeltStations are shipped with a
default RF configuration. It is highly recommended that you change
your system from the default to ensure proper RF performance
especially in the presence of other Tempest systems.

9

9

A BeltStation must be paired with a BaseStation for any
communication to take place. Pairing should be done AFTER the
default RF configuration is changed on the BaseStation.

9

9

Charge the BeltStation batteries prior to starting set-up.