Controller

Specification

Details

Component description

Microprocessor-controlled and menu-driven controller that operates the sensor and
displays measured values.

Operating temperature

-20 to 60 ºC (-4 to 140 ºF); 95% relative humidity, non-condensing with sensor load
<7 W; -20 to 50 ºC (-4 to 104 ºF) with sensor load <28 W

Storage temperature

-20 to 70 ºC (-4 to 158 ºF); 95% relative humidity, non-condensing

Enclosure

1

NEMA 4X/IP66 metal enclosure with a corrosion-resistant finish

Power requirements

AC powered controller: 100-240 VAC ±10%, 50/60 Hz; Power 50 VA with 7 W
sensor/network module load, 100 VA with 28 W sensor/network module load
(optional Modbus, RS232/RS485, Profibus DPV1 or HART network connection).

24 VDC powered controller: 24 VDC—15%, + 20%; Power 15 W with 7 W
sensor/network module load, 40 W with 28 W sensor/network module load (optional
Modbus, RS232/RS485, Profibus DPV1 or HART network connection).

Altitude requirements

Standard 2000 m (6562 ft) ASL (Above Sea Level)

Pollution
degree/Installation
category

Polution Degree 2; Installation Category II

Outputs

Two analog (0-20 mA or 4-20 mA) outputs. Each analog output can be assigned to
represent a measured parameter such as pH, temperature, flow or calculated
values. Optional module supplies three additional analog outputs (5 total).

Relays

Four SPDT, user-configured contacts, rated 250 VAC, 5 Amp resistive maximum for
the AC powered controller and 24 VDC, 5A resistive maximum for the DC powered
controller. Relays are designed for connection to AC Mains circuits (i.e., whenever
the controller is operated with 115 - 240 VAC power) or DC circuits (i.e., whenever
the controller is operated with 24 VDC power).

Dimensions

½ DIN—144 x 144 x 180.9 mm (5.7 x 5.7 x 7.12 in.)

Weight

1.7 kg (3.75 lb)

Compliance information

2

CE approved (with all sensor types). Listed for use in general locations to UL and
CSA safety standards by ETL (with all sensor types).
Certain AC mains powered models are listed for use in general safety locations to
UL and CSA safety standards by Underwriters Laboratories (with all sensor types).

Digital communication

Optional Modbus, RS232/RS485, Profibus DPV1 or HART network connection for
data transmission

Data logging

Secure Digital Card (32 GB maximum) or special RS232 cable connector for data
logging and performing software updates. The controller will keep approximately
20,000 data points per sensor.

Warranty

2 years

1

Units that have the Underwriters Laboratories (UL) certification are intended for indoor use only and do not
have a NEMA 4X/IP66 rating.

2

DC powered units are not listed by UL.

General information

In no event will the manufacturer be liable for direct, indirect, special, incidental or consequential
damages resulting from any defect or omission in this manual. The manufacturer reserves the right to
make changes in this manual and the products it describes at any time, without notice or obligation.
Revised editions are found on the manufacturer’s website.

4 English

Advertising