INSTEON Dimmer Module - 2632-422 (France), 2632-432 (Germany), 2632-442 (UK), 2632-522 (AUS/NZ) Manual User Manual

Page 14

Advertising
background image

Page 14 of 16

2632-422/2632-432/2632-442/2632-522 - Rev: 1/21/2014 7:46 AM

The controller can
turn off Dimmer
Module, but Dimmer
Module does not turn
on when I send an on
command from the
controller

Dimmer Module may be
added to a scene at its off
state

Re-add Dimmer Module to a scene as a controller
while the load is on. See

Make Dimmer Module a

Controller

.

The load is buzzing
when on or dim

The dimming component
inside Dimmer Module
“chops” the powerline sine
wave to reduce the power

The bulb filaments are vibrating. Use rough-service,
130 Volt, or appliance-grade bulbs to reduce the
noise

Run Dimmer Module in the full-on mode or switch to
an On/Off Module

The load only turns
off when I tap a
button on the
controller but I can
brighten or dim it

The on-level may be set to
very dim or full-off

Re-add Dimmer Module to the controller at a brighter
on-level. See

Make Dimmer Module a Responder

.

Dimmer Module is
locked up

A surge or excessive
noise on the powerline
may have locked it up

Unplug Dimmer Module for 10 seconds and then
reinstall

If the above doesn’t work, perform a factory reset.
See

Factory Reset.

The lamp does not
turn on when I
manually activate the
lamp’s switch

Dimmer Module may be
off

Turn on Dimmer Module using the paddle on the
side of the module

Bulb may be burnt out

Replace the lamp’s bulb

The load is not being
controlled by Dimmer
Module

The load may not be
getting power

Make sure the load’s built-in switch is in the on
position

Advertising