Check fuse to ensure it is not broken.

The switch I'm replacing
only has two wires

DIN Rail needs a Neutral wire
in order to operate

Look in the rear of the box for a group of wires all tied
together with a wire nut. Those are the Neutral wires.

Pull a Neutral from nearby junction box

DIN Rail is not receiving
signals from a controller

DIN Rail and the controller
are not within range of each
other

Install additional INSTEON devices to strengthen
INSTEON signals

US applications: Add a Range Extender

Move controller within range of DIN Rail

The controller is plugged into
a power strip

Power line signals can't travel through some power filters.
Plugging the controller directly into a wall outlet works
best.

Other appliance(s) are
causing line noise

Install filters where device(s) are causing line noise

Install additional INSTEON devices to strengthen
INSTEON signals

The load turned on by
itself

Another controller, a timer, or
stray X10 signals triggered
DIN Rail

Install a power line signal blocker in your home to keep
X10 signals from neighboring homes from interfering.
Consider not using DIN Rail in X10 mode.

DIN Rail may have an
undesired responder
membership

Use software to remove membership or perform a factory
reset

DIN Rail responds to on
commands but not off
commands

Load connected to DIN Rail is
producing electrical noise that
is interfering with DIN Rail
reception of power line signal

Install an in-line noise filter between the load and DIN Rail

Install additional INSTEON devices to strengthen
INSTEON signals

When I press a button on
DIN Rail, it takes a long
time for other INSTEON
devices it is controlling to
respond

DIN Rail is trying to control a
scene responder that is not
powered on

Connect power to the device

If the INSTEON device is still available, remove it from
DIN Rail and then re-add it

Perform a factory reset

DIN Rail is locked up

A surge or excessive noise
on the power line occurred

Power cycle the device

Perform a factory reset

DIN Rail can turn off my
responder, but nothing
happens when I send an
on

Responder scene level is off Add responder to scene again at desired scene on-level

Controller can turn off DIN
Rail, DIN Rail does not
respond to on

DIN Rail may be added to a
scene at its off state

Add DIN Rail to scene again at desired scene on-level

DIN Rail still controls
devices even after factory
reset

Scene memberships exist in
the responder

Remove responder from DIN Rail scene