Error blink, Insteon setup, Insteon controllers, responders and links – INSTEON DIN Rail On/Off - 2453-222 (US), 2453-422 (EU), 2453-522 (AUS/NZ) Manual User Manual

Page 7: Make din rail a responder, Make din rail a controller

Advertising
background image

Page 7 of 16

2453-222/2453-422/2453-522 - Rev: 1/21/2014 7:51 AM

LED will start blinking green

4) Tap set button once

LED will start double-blinking green

5) Press and hold set button until it beeps

LED will turn green (at brightness of connected load)

6) Press and hold DIN Rail on/off buttons to brighten or dim LED to desired brightness
7) Tap set button until it double-beeps

DIN Rail will double beep and return to ready mode

Error Blink

By default, DIN Rail LED blinks red for a few seconds to acknowledge a communication error with a responder. This
setting is adjustable via software or central controller only.

INSTEON Setup

Some products have subtle differences in their setup procedures. Please refer to the other device’s owner’s manual
for details.

INSTEON Controllers, Responders and Links

Let’s define a few terms.

• The INSTEON “transmitter” is called a controller
• The INSTEON “receiver” is called a responder

Note: Some devices are controllers only (e.g., motion sensors, handheld remotes), some are responders only (e.g.,
FanLinc), and some can be controllers and responders (e.g., switches and dimmers).

• The association between the controller and responder is called a link

Note that a link is one way. If you want control the other way (making the responder a controller), and the devices are
capable of it, simply add a link “the other way.”

Make DIN Rail a Responder

Control DIN Rail from another INSTEON device:
1) Press and hold controller button until it beeps

Controller LED will start blinking

2) Tap DIN Rail paddle top or bottom to adjust load to on or off when scene
is activated

Connected load will respond appropriately

3) Press and hold DIN Rail set button until it double-beeps

Controller will double-beep and its LED will stop blinking

4) Test by tapping controller button on and off

Connected load will return to the state set in step #2

Note:

-

The link just created is one way. See “Make DIN Rail a Controller” to add another link to keep the two products
in synch, or see “Groups” section.

Make DIN Rail a Controller

Use DIN Rail to control other INSTEON devices:

1)

Press and hold DIN Rail set button until it beeps

DIN Rail LED will start blinking green

Controller

Responder

Link

DIN Rail

(Responder)

Controller

Advertising