Make Micro Module a Controller of Multiple Responders

1) Press and hold Micro module set button until it beeps

LED will start blinking green

2) Tap Micro module set button

LED will start double-blinking green

3) For each responder you are adding:

a. Adjust responder to desired scene brightness/state
b. Press and hold set button until it double-beeps

4) Tap Micro module set button

Micro module will beep and LED will stop blinking

5) Test by tapping switch wired into Micro module on and off

All the responders will turn on and off

Remove Micro Module as a Controller

If you no longer want Micro module to control another device (or are removing Micro module from your
network) it is important that you follow the instructions below for each responder.

1) Press and hold Micro module set button until it beeps

LED will start blinking green

2) Press and hold Micro module set button until it beeps a second time

LED will start blinking red

3) Press and hold responder set button until it double-beeps

Micro module will double-beep and LED will stop blinking

4) Test by tapping Micro module on and off

Former responder will not respond

Remove Micro Module as a Responder

If you no longer want a controller button to control Micro module, follow these directions.
Note: If you ever wish to uninstall Micro module, it is important that you remove all Micro module
responder links. Otherwise, controllers will repetitively retry commands, creating network delays.

1) Press and hold controller button until it beeps

LED will start blinking green

2) Press and hold controller button until it beeps a second time

LED will start blinking red

3) Press and hold Micro module set button until it double-beeps

Controller LED will stop blinking

4) Test by tapping controller button on and off

Micro module will no longer respond

Remove Micro Module as a Controller of Multiple Responders

1) Press and hold Micro module set button until it beeps

LED will start blinking green

2) Press and hold Micro module set button until it beeps a second time

LED will start blinking red

3) Tap Micro module set button

LED will start double-blinking red

4) For each responder you are removing:

a. Press and hold set button until it double-beeps

5) Tap Micro module set button