Installation – INSTEON Micro Dimmer - 2442-222 (US), 2442-422 (EU), 2442-522 (AUS/NZ) Manual User Manual

Page 6

Advertising
background image

Page 6 of 24

2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM

Installation

1)

Write down the INSTEON ID found on the back of the unit (XX.XX.XX)

2)

Turn off breaker/fuse and verify that the power is off

3)

Disconnect wires from existing switch, fixture or outlet and prep all wires to be connected to Micro
module, with 3/16” (5mm) of bare wire on the ends

4)

Connect wires per diagram which corresponds to your installation

Note: sense lines carry very low current (~0.35mA 240V, ~0.17mA for 120V)

5)

After ensuring wires are firmly connected and that there is no exposed wire, turn on breaker/fuse

After a few seconds, load will turn on (if wired into switch or fixture) and Micro module LED will turn
green

6)

Test by tapping Micro module on/off buttons

Load will turn on and off

Micro Module LED will turn green when load is on and red when load is off

7)

If installing a single momentary or dual momentary switch

a)

Press and hold set button until it beeps

Advertising