Identify switch type – INSTEON Micro Dimmer - 2442-222 (US), 2442-422 (EU), 2442-522 (AUS/NZ) Manual User Manual

Page 5

Advertising
background image

Page 5 of 24

2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM

specifications. If this device supports dimming, please note that dimming an inductive load, such as a fan or transformer,
could cause damage to the dimmer, the load bearing device, or both. If the manufacturer of the load device does not
recommend dimming, use a non-dimming INSTEON on/off switch. USER ASSUMES ALL RISKS ASSOCIATED WITH
DIMMING AN INDUCTIVE LOAD.

Identifying the Electrical Wires in Your Home (North America only)

-

Line: usually black (may also be called hot, live or power), carries 120VAC electricity into the wall box

-

Neutral: usually white or white wire bundle, commonly daisy-chained from box to box

-

Load: usually black, from a separate cable jacket

-

Ground: bare copper wire or metal fixture (if grounded)

Identifying the Electrical Wires in Your Home (Europe/Australia/New Zealand)

-

As wire colors vary from country to country, make sure you always check your electrical wires with a voltage meter to
correctly identify line, load, neutral and ground wires

-

If you have any questions, consult an electrician or your electricity supplier to learn more about your country’s wiring colors
and labels

IMPORTANT!
If you have any difficulties or questions, consult an electrician. If you are not knowledgeable about, and comfortable with,
electrical circuitry, you should have a qualified electrician install the product for you.

Identify Switch Type

Before you install Micro module behind a switch, you must determine which switch operation mode
applies to your switch—latching, single momentary or dual momentary—as each is wired differently:

Latching (default mode): Switch has no central position. It can be tapped on both the top and

bottom and remains in that state once released.

Single momentary: Switch can only be tapped in one location. It returns to central position once

released.

Dual momentary: Switch can be tapped on both the top and bottom. It returns to central position

once released.

Note: If you are installing Micro module in a fixture box, switch operation mode does not apply.