Start-up continued, Start-up and operation, If using another means of chlorine support – King Technology FROG Leap Model 7800 User Manual

Page 6

Advertising
background image

6

Start-up and Operation

Set control dial by matching up the parameters of your pool on the chart below. THIS IS A STARTING POINT ONLY and may
need to be adjusted to fit your individual pool needs. See #8 below for directions. IMPORTANT: Pump run times less than
8 hours could result in under chlorination due to inadequate flow through the System.

7.

For the first week test the pool water
daily for free chlorine with FROG

®

Brand

Test Strips to ensure correct dial setting.
Continue to test weekly throughout the
season.

8.

After each testing, adjust the dial
up by 1/2 increment if the free
chlorine reading has dropped
below 0.5 ppm or adjust down by
1/2 increment if the reading has
risen above 1.0 ppm. Continue
this process each day until the free
chlorine reading stabilizes to at
least 0.5 ppm.

Remember to adjust dial by 1/2 increments only in
order to prevent over chlorination which may bleach pool
surfaces.

Shock pool every two weeks or as needed
to maintain water quality. Follow label
directions on the shock treatment used.

6.

Set dial to Setting 5. Maintain a
minimum chlorine reading of 0.5
ppm with a chlorine delivery device
or hand feeding.

7.

Shock pool every two weeks or as needed
to maintain water quality. Follow label
directions on the shock treatment used.

If using another means of chlorine support

, follow

steps 1-5 on page 5 then continue below.

Find your starting dial setting by matching up the parameters of your pool on
the above chart. A pool with approximately 12,000 gallons with a 1 horse pump
running 12 hours a day would require a starting setting of 4.5.

* – Bypass installation recommended.

RECOMMENDED FLOW RATE: 20-60 gpm

NR – This pump size is not recommended for this size pool.

Most common pool size

9.

Do not add shock in or near the
skimmer or into the FROG Leap

I

nfuzer™ as it could damage

equipment, risk potential
explosion or discolor your pool
surface.

Do not add shock in or near the
skimmer or into the FROG Leap

I

nfuzer™ as it could damage

equipment, risk potential
explosion or discolor your pool
surface.

24 HOUR, LOW SPEED PUMP RUN TIME
In order to ensure proper performance when running the pump on
low speed for 24 hours per day or high speed less than 6 hours
per day, bleed the air while the pump is on by unscrewing the cap
knob until water appears. Then screw the knob back on. Repeat
this process each time the cap is removed for any reason. Set
the control dial at 6 and follow the adjustment directions in Step
8 to determine the correct setting for your pool.

POOL SIZE

Gallons Diameter

8 HOUR PUMP RUN TIME

12 HOUR PUMP RUN TIME

24 HOUR PUMP RUN TIME

PUMP SIZE

1/2 hp 3/4 hp 1 hp 1 1/2 hp

PUMP SIZE

1/2 hp 3/4 hp 1 hp 1 1/2 hp

PUMP SIZE

1/2 hp 3/4 hp 1 hp 1 1/2 hp

7,000 (18’)

5.0

4.5

4.0

3.5

4.5

4.0

3.0

5.0*

3.5

3.0

2.5

4.0*

9,000 (21’)

5.5

5.0

4.5

4.0

5.0

4.5

4.0

5.5*

4.0

3.5

3.0

4.5*

12,000 (24’)

6.0

5.5

5.0

4.5

5.5

5.0

4.5

4.0

4.5

4.0

3.5

5.0*

15,000

NR

6.0

5.5

5.0

6.0

5.5

5.0

4.5

5.0

4.5

4.0

3.5

20,000

NR

NR

6.0

5.5

NR

6.0

5.5

5.0

5.5

5.0

4.5

4.0

25,000

NR

NR

6.5

6.0

NR

6.5

6.0

5.5

6.0

5.5

5.0

4.5

POOL SIZE

Gallons Diameter

12 HOUR PUMP RUN TIME

PUMP SIZE

1/2 hp 3/4 hp 1 hp 1 1/2 hp

7,000 (18’)

4.5

4.0

3.0

5.0*

9,000 (21’)

5.0

4.5

4.0

5.5*

12,000 (24’)

5.5

5.0

4.5

4.0

15,000

6.0

5.5

5.0

4.5

20,000

NR

6.0

5.5

5.0

25,000

NR

6.5

6.0

5.5

Advertising