If under chlorinating

Begin with Option 1 and continue with other options if necessary

Pool

Strips

Test

and

Spa

Remember to adjust dial by 1/2
increments only. Higher than sug-
gested settings could result in over
chlorination and/or bleached pool
surfaces.

To start...

1

3

4 5 6 7

9

BROMINE

P

O

O

L

S

2

TRICHLOR

MIN

MAX

8

L

A

R

G

E

R

S

P

A

S

S

M

A

L

LE

R

PO

O

LS

LA

RG

E

R

P

O

O

L

S

MA

Setting
Control Dial

Switch from
1 inch tablets
to 3 inch pucks.

4.

Remove cap and immediately

stand back to avoid inhaling
fumes.

Switch from
3 inch pucks
to 1 inch tablets.

Try bleeding the air,
soaking tablets for
greater output.

1.

For all pools using chlorine...... set the control dial at #2.

For all pools using bromine ......set the control dial at #4. With
bromine only, bleed air from unit by partially unscrewing back knob
on Model 920 or cap knob on Models 940, 960 & 980 while the pump
is running until water appears. Tighten knob.

5.

Make sure all

small particles have
dissolved and been
flushed out of
feeder. Fill unit with
new chemical.
DO NOT MIX
BROMINE AND
CHLORINE.
Do not
put small particles in feeder

Changing Chemicals

continued.

Always wear protection for eyes, skin & clothing. Avoid sparks, open flame or smoking when handling chemicals.

1

3

4 5 6

2

minimum

L

A

R

G

E

R

S

P

A

S

OPTION 1

OPTION 2

OPTION 3

OPTION 4

OPTION 3

OPTION 2

OPTION 1

If over chlorinating

Begin with Option 1 and continue with other options if necessary

2.

For the first

week or so, test
the water daily
for free chlorine
or bromine.

3.

After day one, adjust the dial

up by 1/2 increment if the reading
has dropped or down by 1/2 incre-
ment if the reading has risen.
Continue this process each day
until the reading stabilizes at your
desired level between 1.0 and 3.0
ppm.

4.

For

Models 940,
960 & 980
use the
handle end of
cap tool if the
dial is hard to
turn.

Increase the
number of
hours your
pump runs
per day.

If reading dropped below 1.0 ppm, shock pool.
Turn control dial to minimum when shocking
and NEVER ADD SHOCK IN OR NEAR THE
SKIMMER. Reset dial 1/2 setting higher than
before and continue monitoring daily until
desired chemical level is acheived.

Decrease the
number of hours
your pump runs
per day. Water
must circulate fully
once a day.

Turn dial to minimum or
Setting 0. When reading
drops to desired ppm, reset
dial 1 setting lower than the
starting dial setting and
continue monitoring daily.

When using slow dissolving trichlor, the Perform-Max should be operated based on its normal erosion design where
only the bottom layer of tablets are wetted. This provides better controllability and longer lasting sanitation per refill.
When using bromine, the Perform-Max should be operated as a soaking feeder as this chemical works best when
all tablets are wetted. Therefore bleeding the air on these units is recommended when using bromine.

7.

Replace knob.

8.

For proper initial setting

continue to next section: Setting
Control Dial.

6.

Replace cap by hand only.

DO NOT OVER TIGHTEN.
Do not use cap tool to tighten
cap. For removal only.

1

3

4 5 6 7

9

BRO

MINE

P

O

O

L

S

2

TRICHLOR

MIN

MAX

8

L

A

R

G

E

R

S

P

A

S

S

M

A

L

L

E

R

P

OO

LS

LA

RG

E

R

P

O

O

L

S

MA

Models 940, 960, 980

Model 920

Models 940, 960, 980

Model 920

Models 940, 960, 980

Model 920

Models 940, 960, 980

Model 920

Troubleshooting:

Contact your dealer or King Technology’s Customer Service Department at 800-222-0169, if the steps below do not solve the situation.