CONTREX ML-Drive User Manual

Page 134

Advertising
background image

A-2

Digital Outputs:

Open-Collector Driver (ULN2003)
(50 VDC max, 200 mA continuous, 500 mA peak)
Optically Isolated
Drive Enable
Alarm

Drive Output:

Phase Fired - Single Quadrant
0 - 90 VDC, 10.0 FLA, 1/4 to 1 HP (115V version)
0 - 180 VDC, 10.0 FLA, 1/2 to 2 HP (230V version)
PM Motors

Current Limit:

4.0 to 10.0 Amps RMS
4.0 to 15.0 Amps Peak

Aux Supply:

+5VDC + 5%
150 mA, Max
non-isolated

Serial Interface:

RS485
300 to 9600 Baud
Full parameter access and control

Power Requirements:

115 +15% VAC (model # 3200-1933)
230 +15% VAC (model # 3200-1934)
50/60 Hz
0.1 Amp + motor current

Line Loss:

10 mSec ride through

Operating Temperature:

0

°

to 55

°

C Int. Enclosure

0

°

to 40

°

C Ext. Ambient temperature when

installed in an enclosure no smaller than 12" X 10" X 8"

Storage Temperature:

-25

°

to 70

°

C

Humidity:

0 to 95% non-condensing

Physical Dimensions:

4.0 inches height
4.0 inches width
6.0 inches depth (Interior Panel)

Faceplate Rating:

Nema 4, 4X, 12, 13
IP65

Environment:

The ML-Drive shall be installed in a pollution
degree 2 macro - environment.

Altitude:

To 3,300 Feet (1000 meters)

Weight:

46 ounces

Advertising