CONTREX ML-Drive User Manual
Page 134
A-2
Digital Outputs:
Open-Collector Driver (ULN2003)
(50 VDC max, 200 mA continuous, 500 mA peak)
Optically Isolated
Drive Enable
Alarm
Drive Output:
Phase Fired - Single Quadrant
0 - 90 VDC, 10.0 FLA, 1/4 to 1 HP (115V version)
0 - 180 VDC, 10.0 FLA, 1/2 to 2 HP (230V version)
PM Motors
Current Limit:
4.0 to 10.0 Amps RMS
4.0 to 15.0 Amps Peak
Aux Supply:
+5VDC + 5%
150 mA, Max
non-isolated
Serial Interface:
RS485
300 to 9600 Baud
Full parameter access and control
Power Requirements:
115 +15% VAC (model # 3200-1933)
230 +15% VAC (model # 3200-1934)
50/60 Hz
0.1 Amp + motor current
Line Loss:
10 mSec ride through
Operating Temperature:
0
°
to 55
°
C Int. Enclosure
0
°
to 40
°
C Ext. Ambient temperature when
installed in an enclosure no smaller than 12" X 10" X 8"
Storage Temperature:
-25
°
to 70
°
C
Humidity:
0 to 95% non-condensing
Physical Dimensions:
4.0 inches height
4.0 inches width
6.0 inches depth (Interior Panel)
Faceplate Rating:
Nema 4, 4X, 12, 13
IP65
Environment:
The ML-Drive shall be installed in a pollution
degree 2 macro - environment.
Altitude:
To 3,300 Feet (1000 meters)
Weight:
46 ounces