455 d c, Ontrol, Anel – Controlled Products Systems Group 1042011 User Manual
Page 21: Nstallation, Nstructions, Advanced programming

Page 21
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
T
HE
455 D C
ONTROL
P
ANEL
I
NSTALLATION
I
NSTRUCTIONS
F
AIL
S
AFE
:
If this function is activated,
it enables a function test of
the photocells before any
gate movement.
Y = Enable
No = Disabled
P
RE
F
LASHING
(5
S
):
5s before start of move-
ment.
Y = Enable
No = Disabled
E
LECTRIC
L
OCK
ON
L
EAF
2:
For using the electric lock on
leaf 2 instead of on leaf 1.
Y = Enable
No = Disabled
ADVANCED PROGRAMMING
Display Function Default
M
AXIMUM
T
ORQUE
AT
I
NITIAL
T
HRUST
: The motors oper-
ate at maximum torque
(ignoring the torque set-
ting) at start of movement.
Useful for heavy leaves.
Y = Enable
No = Disabled
L
AST
S
TROKE
AT
C
LOSING
:
The motors are activated at
full speed for 1s to facili-
tate locking of the electric
lock.
Y = Enable
No = Disabled
R
EVERSING
S
TROKE
:
Before opening, while the
gate is closed, the motors
thrust to close for 2 s thus
facilitating release of the
electric lock.
Y = Enable
No = Disabled
L
EAF
2 O
PENING
D
ELAY
(2
S
):
Enables delayed start of
leaf 2, avoiding interfer-
ence between leaves.
Y = Enable
I
NDICATOR
-L
ICHT
:
If 0 is selected, the output func-
tions as a standard indicator-light
(lite at opening and pause, flashing
at closing, and off when gate
closed). Time can be adjusted
from 0 to 59s in 1s increments,
and from 1.0 to 4.1 min. in 10s
steps.
0 = Standard Indicator-Light
From 1 to 4.1 = Timed Output
C
LOSING
P
HOTOCELLS
REVERSE
AT
RE-
LEASE
: Enable this function if you
want the closing photocells to stop
the gate and reverse it after the
beam is cleared. Default setting is
immediate reverse.
Y = Enable
No = Disabled
A.D.M.A.P. F
UNCTION
:
If this function is enabled, the
safety devices to comply with
French standard NFP 25/362.
Y = Enable
No = Disabled
A
SSISTANCE
R
EQUEST
(
COMBINED
WITH
NEXT
FUNCTION
): If activated, at the
end of countdown (settable with the
next function, i.e. “Cycle program-
ming”) it effects 8s of pre-flashing
at every Open pulse (job request).
Can be useful for setting scheduled
maintenance jobs.
Y = Enable
No = Disabled
C
YCLE
P
ROGRAMMING
:
For setting count down of system
operation cycles. Settable (in thou-
sands) from 0 to 99 thousand cy-
cles. The displayed value is up-
dated as cycles proceed. This func-
tion can be used to check use of
the board or to exploit the
“Assistance Request” function.
E
XTRA
W
ORK
T
IME
:
When operating, if reversing occurs,
and if the leaf does not reach its
end contact point, you can activate
this function to increase work time.
Y = A
CTIVE
N
O
= D
ISABLED
E
XIT
P
ROGRAMMING
:
Exit from programming.