Controlled Products Systems Group 1042011 User Manual

Page 9

Advertising
background image

Page 9

February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual

Figure 5. Important mounting dimensions for

outward swing 400 operators, top view

A

TTACH

THE

O

PERATOR

TO

THE

G

ATE

Re-attach the operator to the mounting brackets. Once
the operator is mounted and level, remove the vent
screw from the bottom of the rear flange. (See Figure 1)


WARNING!

Failure to remove the vent screw

may result in erratic operation of the operator or

blown

seals.

Slowly move the gate open and close.

WARNING!

The piston should not bottom out in

either direction. Doing so will seriously damage

the

operator.


Be sure that the gate reaches the positive stop before

the piston bottoms out. Adjust the swivel joint if
necessary.

Once the operator is secure, attach the protective cover
to the front flange with the tie rods and end cap
provided.


Note

: Lubricating the threads of the protective

cover tie rods can prevent them from freezing up

and breaking if operator is ever removed for

service.


Once the protective cover is installed, swing the gate to
ensure that it does not contact the cover at any point of

the swing.

Re-engage the operator by turning the red knob

clockwise until snug. (see Figure 3)

Figure 6. Locking Cap

Assembly


A

DJUST

THE

OPERATOR

PRESSURES

The 400 Operator has an anti-crushing safety device
(operator pressure) which limits the operator’s force if
an obstacle is encountered while the gate is moving.


To adjust the anti-crushing safety device do the
following procedures:

Lift the key lock cover (figure 3) and insert the
manual release key.

Turn the key 90° clockwise to open the locking cap
cover.

Lift up the cover.

Refer to figure 6 for the following procedures)

Remove the screw (3) which secures the knob (4)

and then remove the knob.

Locate the pressure adjustment (by-pass) screws (5

and 6)

Opening pressure screw

(green wording = gate opening
direction)

Closing pressure screw (red

wording = gate closing direction

N O T E : F A A C

recommends the maximum
pressure to be set at 33lbs at the

leading edge of the gate leaf.

WARNING: Do Not Exceed

the UL regulations of 45lbs. At
the leading edge of the gate

leaf

Dimensions, In. (cm)

400 Standard, Rapid, Slow and EG 400 Long (EG)

90°

115°

125°

A

5 (12.7)

5 3/4 (14.6)

4 3/4 (13)

B

5 (12.7)

7 (17.8)

6 5/8 (17)

C

27 9/16 (70)

32 3/4 (93.19)

32 3/4 (83.19)

D

No Limit

No Limit

No Limit

E

Must be less than A

Advertising
This manual is related to the following products: