Page 23

February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual

flashing.
The procedure has ended and the gate is ready to

operate, using default slow down automatically set
by the control panel.

C

OMPLETE

L

EARNING

N

OTES

:

If only one gate operator (1) is used, you
must go through the entire programming

procedure, as if you were programming a
gate operator (2). When the gate operator
(1) has finished opening, supply 4 open

commands until the gate operator begins
to close, and then resume normal
operations.


Close the gates, enter “B

ASIC

P

ROGRAMMING

, select

the TIME LEARNING function and press the + push-

button for more than 3 seconds: the display begins
flashing and leaf 1 begins opening movement. The
following functions can be commanded by the OPEN

A command (by radio control or key push-button):

When gate operator (1) reaches the
position that you want it to slow down, an

open command must be given to start the
slow down phase. When the gate operator
reaches its positive stop, the operator will

automatically shut off.

An open command must be given to start
opening gate operator (2).

When gate operator (2) reaches the
position that you want it to slow down, an
open command must be given to start the

slow down phase. When the gate operator
reaches its positive stop, the operator will
automatically shut off.

An open command must be given to start
closing gate operator (2).

When gate operator (2) reaches the position
that you want it to slow down, an open
command must be given to start the slow
down phase. When the gate operator reaches

its positive stop, the operator will
automatically shut off.

An open command must be given to start
closing gate operator (1).

When gate operator (1) reaches the position
that you want it to slow down, an open

command must be given to start the slow
down phase. When the gate operator reaches

its positive stop, the operator will
automatically shut off.

The display stops flashing and the gate is ready for
normal operation.

N

OTES

:

The open command to slow down the gate
should be given before the gate reaches the
positive stop to prevent the gate from hitting

the stop at full speed. The positive stop could
be mistaken for an obstacle and then upon
hitting it, the gate(s) would automatically

reverse on contact.


A

UTOMATED

S

YSTEM

T

EST


When you have finished programming, check if the

system is operating correctly.

Most important of all, check that the force is adequately

adjusted and that the safety devices are operating
correctly.

If pressure adjustments on hydraulic operators are not
set before programming. It may need to be
reprogrammed for desired results.

T

HE

455 D C

ONTROL

P

ANEL

I

NSTALLATION

I

NSTRUCTIONS

Magnetic Lock

N.C.

N.O.

COM

17

14

18

21

12 vac

Relay

+

-

Lock

Magnetic Lock Diagram