SECTION 1 - INSTALLATION

Prior to beginning the installation of the swing gate operator, we suggest that you become familiar
with the instructions, illustrations, and wiring guide-lines in this manual. This will help insure that your
installation is performed in an efficient and professional manner.

The proper installation of the vehicular swing gate operator is an extremely important and integral part
of the overall access control system. Check all local building ordinances and building codes prior to
installing this operator. Be sure your installation is in compliance with local codes.

Class of Operation:

Model 6050 - Class I only, Model 6100 - Class I, II, III, IV

Type of Gate:

Vehicular Swing Gates Only

Horsepower:

Model 6050 - 1/3 H.P., Model 6100 - 1/2 H.P.

Voltage / Phase:

115 VAC Single-phase only

Current:

Model 6050 - 4.3 amps, Model 6100 - 5.4 amps

Max Gate Weight:

Model 6050 - 400 Lbs., Model 6100 - 500 Lbs.

Max Gate Length:

Model 6050 - 10 Ft., Model 6100 - 14 Ft.

Cycles / Hr:

Model 6050 – 10/Hr, Model 6100 – 60/Hr

Speed:

90° in approximately 12 seconds

Entrapment Protection:

Primary - Inherent adjustable clutch (Type C)

Secondary - Inherent entrapment sensing system (Type A)
and provision for connection of a non-contact sensor (Type
B1)

1.1 SPECIFICATIONS

Figure 1

27.75

6100 W/BATTERY BACKUP

13.25

23.00

11.00

6.0

Advertising