SECTION 5 – MAINTENANCE AND TROUBLESHOOTING

Inspection and service of this gate operator by a qualified technician should be performed anytime a
malfunction is observed or suspected. High cycle usage may require more frequent service checks.

When servicing the gate operator, always check any secondary (external) reversing devices (loops,
photo eyes, etc.) for proper operation. If external reversing devices cannot be made operable, do not
place this operator in service until the malfunction can be identified and corrected.

Always check the inherent reversing system when performing any maintenance. If the
inherent reversing system cannot be made operable, remove this operator from service until
the cause of the malfunction is identified and corrected. Keeping this operator in service
when the inherent reversing system is malfunctioning creates a hazard for persons which can
result in serious injury or death should they become entrapped in the gate.

When servicing this gate operator, always turn power OFF!!

5.1 MAINTENANCE

MONTHLY
INTERVAL

MAINTENANCE SCHEDULE

3 6 12

Alarm

Activate the primary (inherent) reverse system by blocking the gate
with a solid object. When the gate reverses, block the gate in the
opposite direction prior to the limit being reached. The entrapment
alarm should activate. Press the reset button to silence the alarm.

Arms

Check set screws and nuts. Check bushings for wear.

Backup System

If operator is equipped with option DC backup system, check to be
sure the system opens the gate upon loss of AC power.

Batteries

If operator is equipped with optional DC backup system, check the
batteries for any leakage or loose connections. Batteries should be
replaced every two years.

Drive Belt

Check for alignment, tightness and wear.

Fire Dept.

Check emergency vehicle access device for proper operation.

Gate

Inspect for damage. Check gate hinges for wear and grease if
necessary.

Gear

Inspect for wear. Grease if necessary. Use only EP Molybdenum
Disulfide (Moly D) grease (DoorKing P/N 2600-770).

Grease

Main shaft zert fitting.

Primary Reverse

System

Check that the gate reverses on contact with an object in both the
opening and closing cycles. Adjust the clutch if necessary.

Loop(s)

Check vehicular reverse and shadow loops for proper operation.

Release

Check manual release for proper operation.

Secondary

Reverse Device

Check secondary (external) reverse device(s) stop or reverse the
gate when activated.

Worm Gear

Inspect for wear and proper alignment.

Complete

Complete check of gate and gate operating system.