Gate Closed
1.4.3 TEST YOUR INSTALLATION
• When the gate is fully closed, the drive and
connecting arms should be in a straight line
as shown in Figure 16.
• Manually open the gate. The connecting arm
should rotate beneath the drive arm and
output shaft. When the gate is fully open, the
drive arm should be directly over the
connecting arm as shown in Figure 17.
• If the gate does not open a full 90°, this means
that the drive arm is less than half the A1-A2
measurement. Re-check this measurement
and reset the drive arm length.
• If the gate opens farther than 90°, this means
that the drive arm is greater than half the A1-
A2 measurement. Re-check this
measurement and reset the drive arm length.
• Shortening the crank arm 1” will stop the gate
2” short. Lengthening the crank arm 1” will
cause the gate to swing 2 inches farther.
• Once you are sure that the gate opens and
closes fully, trim the excess length off of the drive
and connecting arms.
This DoorKing Swing Gate Operator is shipped with two warning signs. The purpose of the warning
sign is to alert uninformed persons, and to remind persons familiar with the gate system, that a
possible hazard exist so that appropriate action can be taken to avoid the hazard or to reduce
exposure to the hazard.
• Permanently install the supplied warning signs in locations
so that the signs are visible by persons on both sides of
the gate.
• Use appropriate hardware such as wood or sheet metal
screws (not supplied) to install the warning signs.
G
a
te
O
p
e
n
Figure 16
Figure 17
1.5 WARNING SIGN INSTALLATION
WARNING
Moving Gate Can Cause
Serious Injury or Death
KEEP CLEAR! Gate may move at any time
without prior warning.
Do not let children operate the gate or play
in the gate area.
This entrance is for vehicles only.
Pedestrians must use separate entrance.
Figure 18