All gate operators

be properly grounded.

A proper ground in a gate operator installation minimizes or prevents damage from an electrical charge, such as a near
lightning strike or an electrical static discharge.
.
Use a single wire for the ground.

splice two wires for the ground. If the wire breaks or is cut, replace it with a

single length.

use two wires for the ground.

Check with your City code for proper earth ground rod type and proper grounding procedures.

DO NOT

NEVER

MUST

OFF

OFF

X

X

ELECTRICAL CONNECTION

Power switch and
electrical connection
box.

Connect black wire to 115 volts AC = Hot.

Connect white wire to AC = Neutral.

Connect ground wire to operator metal frame. Use a
proper

for a ground reference.

Use the shortest and thickest wire possible for ground.

ground rod

For power wires enclosure
use UL listed conduits.

OPERATORS

BE PROPERLY GROUNDED!

MUST

23

For power, a minimum of a
20-Amp dedicated circuit
breaker is needed.