Install power wiring & control station, Wiring specifications, Warning caution warning warning – Controlled Products Systems Group SW4705011G3 User Manual

Page 14

Advertising
background image

14

WARNING

CAUTION

WARNING

WARNING

DISCONNECT POWER AT THE FUSE BOX BEFORE
PROCEEDING.
OPERATOR MUST BE PROPERLY GROUNDED AND
CONNECTED IN ACCORDANCE WITH LOCAL ELEC-
TRICAL CODES. NOTE: THE OPERATOR SHOULD
BE ON A SEPARATE FUSED LINE OF ADEQUATE
CAPACITY.
ALL ELECTRICAL CONNECTIONS MUST BE MADE
BY A QUALIFIED INDIVIDUAL.

INSTALL POWER WIRING & CONTROL STATION

WARNING

CAUTION

WARNING

WARNING

ANY MAINTENANCE TO THE OPERATOR OR IN THE
AREA NEAR THE OPERATOR MUST NOT BE PER-
FORMED UNTIL DISCONNECTING THE ELECTRICAL
POWER AND LOCKING-OUT THE POWER VIA THE
OPERATOR POWER SWITCH. UPON COMPLETION
OF MAINTENANCE THE AREA MUST BE CLEARED
AND SECURED, AT THAT TIME THE UNIT MAY BE
RETURNED TO SERVICE.

NOTE: Calculated using NEC guidelines. Local codes and conditions must be reviewed for suitability of wire installation.

NOTE: All power wiring should be dedicated and protected. Location of primary power disconnect should be

labeled.

WARNING

CAUTION

WARNING

WARNING

DO NOT INSTALL ANY WIRING OR ATTEMPT TO
RUN THE OPERATOR WITHOUT CONSULTING THE
WIRING DIAGRAM. WE RECOMMEND THAT YOU
INSTALL AN OPTIONAL REVERSING EDGE BEFORE
PROCEEDING WITH THE CONTROL STATION
INSTALLATION.

WARNING

CAUTION

WARNING

WARNING

BEFORE INSTALLING POWER WIRING OR CON-
TROL STATIONS BE SURE TO FOLLOW ALL SPECI-
FICATIONS AND WARNINGS DESCRIBED BELOW.
FAILURE TO DO SO MAY RESULT IN SEVERE
INJURY TO PERSONS AND/OR DAMAGE TO OPER-
ATOR.

6

8

10

12

1/2
3/4

1

1/2
3/4

1

1/2
3/4

1

1/2
3/4

1

425
291
213
269
183
134
168

115

84

105

72
53

1845

1107

852

1165

699
537
730
438
337
458
274

211

2557
1827
1278
1614

1152

807

1012

723
506
634
503
316

12789

6394

5115

8072
4035
3228
5064
2532
2025
3171
1585
1269

15987
10657

7993

10089

6726
5044
6330
4220
3165
3964
2643
1982

THREE PHASE

SINGLE PHASE

WIRE LENGTH IN FEET (STRANDED COPPER WIRE)

WIRING SPECIFICATIONS

WIRE GA.

HP

ON A DUAL GATE SYSTEM EACH UNIT MUST BE INSTALLED ON ITS OWN SEPARATE CIRCUITS

115 VAC

230 VAC

230 VAC

460 VAC

575 VAC

Advertising