Optional control devices – Controlled Products Systems Group SW4705011G3 User Manual
Page 19

19
Terminals 9 & 5 - Obstruction Open (Edge/ Photo Eye Input)
Edge Input: See Programming Section
This input will reverse an opening gate to the close limit.
Activating this input when the gate is closing will have no
effect. Note: If upon reversal a second seperate obstruc-
tion is detected (gate edge or R.P.M. sensor), gate will
stop & alarm.
Photo Eye Input: See Programming Section
This input will pause an opening gate. Once the input
(photo eye) is cleared, the gate continues to open.
Activating this input when the gate is closing will have
no effect.
Terminals 10 & 5 - Obstruction Close (Edge/ Photo Eye Input)
Edge Input: See Programming Section
This input will reverse a closing gate to the open
limit. When reaching the open limit the timer to close,
if enabled, will be disabled until another command is given.
Activating this input when the gate is closing will have no
effect. Note: If upon reversal a second seperate obstruc-
tion is detected (gate edge or R.P.M. sensor), gate will
stop & alarm.
Photo Eye Input: See Programming Section
This input will reverse a closing gate to the open
limit. This input will not affect the timer to close.
Activating this input when the gate is closing will
have no effect.
Terminals 3 & 5 - Stop/Reset Control Input
These terminals are intended for use with a single stop/reset
button or the stop control of a three-button station that is
installed within line of site of the gate. This input functions to
stop the gate or to reset the gate after an entrapment fault.
Note: This input uses a normally closed circuit and the
operator will not run until a stop control is installed.
Terminals 4 & 5 - Hard Close Control Input
These terminals are intended for use only with the close con-
trol of a three-button station that is installed within line of sight
of the gate. A momentary activation of this input will cause
the gate to close. Activation of this input for longer than
three seconds will enable the control to be used as a
constant pressure override device. This will allow the user,
in emergencies, to override a failed accessory such as a loop
detector or photo-eye.
Terminals 7 & 5 - Hard Open Control Input
These terminals are intended for use only with the open con-
trol of a three-button station that is installed within line of sight
of the gate. A momentary activation of this input will cause
the gate to open. Activation of this input for longer than
three seconds will enable the control to be used as a
constant pressure override device. This will allow the user,
in emergencies, to override a failed accessory such as a loop
detector or photo-eye.
OPTIONAL CONTROL DEVICES
OBSTRUCTION OPEN (EDGE/PHOTO EYE INPUT)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OBSTRUCTION CLOSE (EDGE/PHOTO EYE INPUT)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
STOP/RESET CONTROL INPUT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
STOP
HARD CLOSE CONTROL INPUT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
CLOSE
HARD OPEN CONROL INPUT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OPEN