Program settings (dip switch #2), Program settings (dip switch #1), Timer to close – Controlled Products Systems Group SW4705011G3 User Manual
Page 22

22
TIMER TO CLOSE ENABLE
This switch (S1-1) enables the auto close timer. The timer
to close feature works in conjunction with the potentiome-
ter located on the board.
SLIDE/SWING
This switch (S1-2) selects slide or swing gate operation,
in order to optimize gate behavior for specific application.
SL = Slide
SW = Swing
RIGHT/LEFT OPERATION
This switch (S1-3) selects the gate opening direction, to
the left or to the right. Right/Left operation is determined
from the inside of fence looking out.
SAVE MODE
This switch (S1-4) stores S1, S2 and S4 DIP switch set-
tings into memory & locks out changes.
Note: For any programming changes to take effect
this switch must be in OFF position.
RT LT
SW SL
RT LT
SW SL
1 2 3 4
ON
SAVE
TTC
ON
S1
RIGHT
1 2 3 4
ON
SAVE
TTC
ON
S1
LEFT
RT LT
SW SL
RT LT
SW SL
1 2 3 4
ON
SAVE
TTC
ON
S1
LOCKED
1 2 3 4
ON
SAVE
TTC
ON
S1
UNLOCKED
RT LT
SW SL
RT LT
SW SL
1 2 3 4
ON
SAVE
TTC
ON
S1
TIMER TO CLOSE
ENABLED
1 2 3 4
ON
SAVE
TTC
ON
S1
TIMER TO CLOSE
DISABLED
RT LT
SW SL
RT LT
SW SL
1 2 3 4
ON
SAVE
TTC
ON
S1
SWING
1 2 3 4
ON
SAVE
TTC
ON
S1
SLIDE
MAGLOCK ENABLE
This switch (S2-1) enables the Maglock feature. On an
open command there will be a half second delay after the
maglock relay is released before the motor starts.
PROGRAM SETTINGS (DIP SWITCH #2)
WARNING ENABLE
This switch (S2-2) enables the gate “in motion” alarm fea-
ture. The alarm will beep 3 seconds prior to movement
and throughout movement.
CLED PH
OPED PH
CLED PH
OPED PH
1 2 3 4
ON
WARN
MAG
ON
S2
1 2 3 4
ON
WARN
MAG
ON
S2
MAGLOCK ENABLED
MAGLOCK DISABLED
CLED PH
OPED PH
CLED PH
OPED PH
1 2 3 4
ON
WARN
MAG
ON
S2
1 2 3 4
ON
WARN
MAG
ON
S2
WARNING ENABLED
WARNING DISABLED
TIMER TO CLOSE
30
SECONDS
180
SECONDS
0
TIMER TO CLOSE
ADJUSTMENT
PROGRAM SETTINGS (DIP SWITCH #1)
NOTE: For all S1, S2 and S4 switch settings to take effect, the Save Mode must be set to the off position.