Program settings (dip switch #2), Program settings (dip switch #1), Timer to close – Controlled Products Systems Group SW4705011G3 User Manual

Page 22

Advertising
background image

22

TIMER TO CLOSE ENABLE
This switch (S1-1) enables the auto close timer. The timer
to close feature works in conjunction with the potentiome-
ter located on the board.

SLIDE/SWING
This switch (S1-2) selects slide or swing gate operation,
in order to optimize gate behavior for specific application.

SL = Slide
SW = Swing

RIGHT/LEFT OPERATION
This switch (S1-3) selects the gate opening direction, to
the left or to the right. Right/Left operation is determined
from the inside of fence looking out.

SAVE MODE
This switch (S1-4) stores S1, S2 and S4 DIP switch set-
tings into memory & locks out changes.
Note: For any programming changes to take effect
this switch must be in OFF position.

RT LT

SW SL

RT LT

SW SL

1 2 3 4

ON

SAVE

TTC

ON

S1

RIGHT

1 2 3 4

ON

SAVE

TTC

ON

S1

LEFT

RT LT

SW SL

RT LT

SW SL

1 2 3 4

ON

SAVE

TTC

ON

S1

LOCKED

1 2 3 4

ON

SAVE

TTC

ON

S1

UNLOCKED

RT LT

SW SL

RT LT

SW SL

1 2 3 4

ON

SAVE

TTC

ON

S1

TIMER TO CLOSE

ENABLED

1 2 3 4

ON

SAVE

TTC

ON

S1

TIMER TO CLOSE

DISABLED

RT LT

SW SL

RT LT

SW SL

1 2 3 4

ON

SAVE

TTC

ON

S1

SWING

1 2 3 4

ON

SAVE

TTC

ON

S1

SLIDE

MAGLOCK ENABLE
This switch (S2-1) enables the Maglock feature. On an
open command there will be a half second delay after the
maglock relay is released before the motor starts.

PROGRAM SETTINGS (DIP SWITCH #2)

WARNING ENABLE
This switch (S2-2) enables the gate “in motion” alarm fea-
ture. The alarm will beep 3 seconds prior to movement
and throughout movement.

CLED PH

OPED PH

CLED PH

OPED PH

1 2 3 4

ON

WARN

MAG

ON

S2

1 2 3 4

ON

WARN

MAG

ON

S2

MAGLOCK ENABLED

MAGLOCK DISABLED

CLED PH

OPED PH

CLED PH

OPED PH

1 2 3 4

ON

WARN

MAG

ON

S2

1 2 3 4

ON

WARN

MAG

ON

S2

WARNING ENABLED

WARNING DISABLED

TIMER TO CLOSE

30
SECONDS

180
SECONDS

0

TIMER TO CLOSE
ADJUSTMENT

PROGRAM SETTINGS (DIP SWITCH #1)

NOTE: For all S1, S2 and S4 switch settings to take effect, the Save Mode must be set to the off position.