Magnum Venus Plastech System One FRP 4101-00-01 User Manual
Page 12
Advertising
FRP SystemOne
Gelcoat
FRP SystemOne
CS1S1Gelcoat Catalyst
Surge Chamber Reassembly
Chapter
5
1.
Install a 7301-9-013 (O-Ring) over the threaded end of the
4104-6-1 (Return Tube Fitting).
2.
Insert the 9201-1-4 (1/8” SS Ball) into the 4104-4-1 (Surge Relief
Valve Body).
3.
Insert the 4104-5-1 (Relief Valve Spring) into the 4104-4-1 (Surge
Relief Valve Body) over the SS Ball.
4.
Thread the 4104-6-1 (Return tube Fitting) into the 4104-4-1 (Surge
Relief Valve Body) compressing the spring between the Tube
Fitting and the Ball.
5.
Fasten the Catalyst Surge Chamber Assembly to the Metering
Pump Assembly.
The Surge Chamber Assembly is complete.
9
Advertising