background image

FRP SystemOne
Gelcoat

FRP SystemOne
CS1S1Gelcoat Catalyst
Surge Chamber Reassembly

Chapter

5

1.

Install a 7301-9-013 (O-Ring) over the threaded end of the
4104-6-1 (Return Tube Fitting).

2.

Insert the 9201-1-4 (1/8” SS Ball) into the 4104-4-1 (Surge Relief

Valve Body).

3.

Insert the 4104-5-1 (Relief Valve Spring) into the 4104-4-1 (Surge

Relief Valve Body) over the SS Ball.

4.

Thread the 4104-6-1 (Return tube Fitting) into the 4104-4-1 (Surge
Relief Valve Body) compressing the spring between the Tube
Fitting and the Ball.

5.

Fasten the Catalyst Surge Chamber Assembly to the Metering
Pump Assembly.

The Surge Chamber Assembly is complete.