FRP SystemOne
Gelcoat

FRP SystemOne
Reassembly of MP.057S1
Gelcoat Metering Pump

Assembly Procedures:

1.

Install 7301-9-013 (O-Ring), and 4101-8-1 (Inlet Tube Fitting) onto
4101-7-1 (Inlet Body).

2.

Insert the 9201-1-14 (7/16” SS Ball) into the 4101-7-1 (Inlet Body).

3.

Position a 7301-9-014 (O-Ring) onto the notched end of the
4101-2-1 (Cylinder).

4.

Screw the notched end of the 4101-2-1 (Cylinder) into the 4101-7-1
(Inlet Body). Turn by hand until it bottoms on the Inlet Body, “snug

tight”.

5

NOTE

Take care not to damage the O-ring on the threads.

NOTE

Care must be taken to not scratch or dent SS Ball.