FRP SystemOne
Gelcoat
FRP SystemOne
Reassembly of MP.057S1
Gelcoat Metering Pump
Assembly Procedures:
1.
Install 7301-9-013 (O-Ring), and 4101-8-1 (Inlet Tube Fitting) onto
4101-7-1 (Inlet Body).
2.
Insert the 9201-1-14 (7/16” SS Ball) into the 4101-7-1 (Inlet Body).
3.
Position a 7301-9-014 (O-Ring) onto the notched end of the
4101-2-1 (Cylinder).
4.
Screw the notched end of the 4101-2-1 (Cylinder) into the 4101-7-1
(Inlet Body). Turn by hand until it bottoms on the Inlet Body, “snug
tight”.
5
NOTE
Take care not to damage the O-ring on the threads.
NOTE
Care must be taken to not scratch or dent SS Ball.