FRP SystemOne

Gelcoat

FRP SystemOne
Disassembly of MP.057S1 Gelcoat
Metering Pump

2

Chapter

2

1.

Remove 4101-15-1 (Check Valve Body) from 4101-14-1 (Outlet
Body) and remove and discard the two 7301-4-013 (O-Rings).

2.

Remove the 4107-17-1 (Spring Retainer) and 4101-16-1
(Compression Spring) from the 4101-15-1 (Check Valve Body),
and remove and discard the 9201-1-7 (7/32” SS Ball).

3.

Loosen 4101-1-1 (Lock Nut) and unscrew the 4101-14-1 (Outlet
Body) from the 4101-2-1 (Cylinder).

4.

Remove the 4101-61 (Seal Retainer) from the 4101-4-1 Piston
Body.

5.

Remove and discard the 7304-2-1 (Piston Seal).

6.

Remove the 4101-4-1 (Piston Body) from the 4101-10-1 (Piston
Rod).

WARNING

Before removing Metering Pump and Surge Chamber assembly
from the Slide Drive, be sure to bleed the fluid pressure from the
system; before disconnecting any hoses or tubes. System may be
under pressure and could cause injury.