Getting started – Magnum Venus Plastech PATRIOT Duo 1:1 DUO-PAT-7-12-SIL User Manual
Page 17

Patriot Duo Unit Manual
Rev. 07/2012
Page | 17
Getting Started:
Air Requirements:
Clean, dry compressed air must be available at 90 – 100 psi (6 – 7 bar) and a minimum
volume of 10 -14 CFM (.3 – .4 m
3
/min.). Air must be provided through an air hose with
a diameter of 0.5 inch (1.3 cm) or greater.
Lubrication:
Throughout this manual, directions are given for lubricating various parts. There are
four types of lubricant used:
If the part contacts resin, use MVP Red Grease (6706-2-1).
If the part is located where it will contact air, use Lubriplate
®
(08465).
Throat Seal Oil (PAT-LS-OIL) used in the oil reservoir of the fluid sections.
Gun Oil (6706-3-1) for Pro gun repair and maintenance
Other Supplies:
Solvent for cleaning.
A small Chip / Paint Brush for cleaning.
Sealable container for the solvent large enough for cleaning gun and pump
part.
Medium Thread Locker (Removable Loctite
®
243 or equivalent)
Spare Mixer Element (07550)