Air Requirements:


Clean, dry compressed air must be available at 90 – 100 psi (6 – 7 bar) and a minimum
volume of 10 -14 CFM (.3 – .4 m

3

/min.). Air must be provided through an air hose with

a diameter of 0.5 inch (1.3 cm) or greater.

Lubrication:


Throughout this manual, directions are given for lubricating various parts. There are
four types of lubricant used:

If the part contacts resin, use MVP Red Grease (6706-2-1).

If the part is located where it will contact air, use Lubriplate

®

(08465).

Throat Seal Oil (PAT-LS-OIL) used in the oil reservoir of the fluid sections.

Gun Oil (6706-3-1) for Pro gun repair and maintenance

Other Supplies:

Solvent for cleaning.

A small Chip / Paint Brush for cleaning.

Sealable container for the solvent large enough for cleaning gun and pump
part.

Medium Thread Locker (Removable Loctite

®

243 or equivalent)

Spare Mixer Element (07550)