Remove and Disassemble Filter:
1. Unscrew the filter cap (FF-5002) from the filter body (FF-5001).
NOTE: The components of the resin accumulator and filter should not be over
tightened.
2. Remove the screen (FF-5099-100) from the filter body (FF-5001).
3. Inspect the screen and clean with solvent.
NOTE: Typically, the screen is a 100-mesh. Mesh size depends on the resin type and
the size of the nozzle tip used on the gun. If you change resin types, you may want to
experiment with a different nozzle tip and/or a different size mesh in your filter screen.
4. Inspect the interior of the filter body and clean with solvent.
5. Check the O-Ring (O-V-022) on the filter cap for wear or damage. Replace if
necessary.
NOTE: If resin is leaking down the side of the filter cap, the O-Ring (O-V-022) is worn
and should be replaced.
Assemble and Install Filter Body:
1. Lubricate the threads of the filter cap (FF-5002) and o-ring (O-V-022) with red grease
(6706-2-1).
2. Place the screen (FF-5099-100) onto the filter cap (FF-5002).
3. Screw the filter cap into the filter body (FF-5001).
Remove Accumulator Bottle:
DANGER: Before disassembling accumulator, relieve fluid pressure and air pressure.
If material is plugging the system, some parts of the system may still contain fluids
under high pressure, even after you have followed normal procedures to relieve the
pressure.
1. Unscrew the surge chamber (SC-2510) from the nipple (PF-HN-08-06).
2. Inspect the interior of the accumulator bottle. Clean with solvent and blow dry with
air if needed.
Install Accumulator Bottle:
1. Screw the nipple (PF-HN-08-06) and surge chamber (SC-2510) into the top of the
filter body (FF-5001).
2. Check for leaks