Magnum Venus Plastech ADVANTAGE User Manual
Page 22

Advantage Gelcoater
Test Flush System
Test the flush system by manually flushing the gun into an appropriate
empty container (see Figure 17). To flush the gun, perform the following
steps:
Hold an appropriate container under the gun-head.
Wearing appropriate safety gear (gloves, goggles, clothes etc.) place
one finger over the nozzle port.
Push button on the left side of the gun for 5 - 7 seconds.
Solvent pours from the mix chamber on the gun-head.
Be sure the flush tank pressure does not exceed 50-70 psi for ProGuns.
CAUTION
Do not overpressurize the flush system.
NOTE
Be sure the gun trigger is not pulled back or locked
back.
CAUTION
When working with machinery that uses pressurized
fluids, wear approved protection for your eyes.
NOTE
Store the solvent in an approved container with the lid
in place to prevent evaporation.
18