Magnum Venus Plastech ADVANTAGE User Manual
Page 45

Advantage Gelcoater
Visually inspect the open ports of the gun block for signs of gelled mate-
rial after flushing.
Remove Fluid Pressure
Follow all warnings and suggestions regarding the use of respirator,
clothing, and appropriate safety procedures recommended by
manufacturers of your material.
Turn PUMP PRESSURE regulator knob counterclockwise until the pres-
sure gauge reads “0”.
Position gun-head over suitable container and pull gun trigger and lock
open to drain fluid pressure from system.
Flush gun block into appropriate container.
Relieve charge from accumulator by inserting a 1/16” rod into charging
valve on top of resin accumulator. (See figure 36)
Figure 36: Relieving Pressure from Accumulator
Clean Catalyst System
WARNING
Solvents such as acetone are extremely flammable.
WARNING
Draining the air charge from accumulators MUST NOT be
done unless resin fluid pressure is relieved from
pumping system
41