WARNING

The washer-extractor should be connected to an individual branch

circuit not shared with lighting or other equipment.

Electrical Specifications HF304, IHF304, IHF075, CHF304, CHF075

304 liters / 75 pounds

Boiler Fed/Steam Heat

Electric Heat

Code

Voltage

Cycle

Phase

Wire

Full Load

Amps

Recommended Circuit

Breaker (US-market)

AWG/mm2

kW Standard

Heating Elements

Full Load

Amps

Recommended

Circuit Breaker (US-

market)

AWG/mm2

US NON-US

US NON-US

N

440-480 50/60

3

3+PE

16

20

20

12/4.0

6x3 kW

42

50

50

8/10.0

P

380-415 50/60

3

3+N+PE 25

30

32

10/6.0

51

60

60

6/16.0

Q

200-240 50/60

3

3+PE

25

30

32

10/6.0

71

80

80

4/25.0

X

200-240 50/60

1/3

2/3+PE N/A N/A

N/A

N/A

N/A N/A

N/A

N/A

Alternative Electric Heat Options

N

440-480 50/60

3

3+PE

3x3 kW +

3x4 kW

46

50

50

8/10.0

P

380-415 50/60

3

3+N+PE

56

60

60

6/16.0

Q

200-240 50/60

3

3+PE

N/A N/A

N/A

N/A

X

200-240 50/60

1/3

2/3+PE

N/A N/A

N/A

N/A

N

440-480 50/60

3

3+PE

6x4 kW

51

60

60

6/16.0

P

380-415 50/60

3

3+N+PE

60

70

70

4/25.0

Q

200-240 50/60

3

3+PE

N/A N/A

N/A

N/A

X

200-240 50/60

1/3

2/3+PE

N/A N/A

N/A

N/A

N

440-480 50/60

3

3+PE

3x6 kW +

3x4 kW

59

70

70

4/25.0

P

380-415 50/60

3

3+N+PE

69

80

80

4/25.0

Q

200-240 50/60

3

3+PE

N/A N/A

N/A

N/A

X

200-240 50/60

1/3

2/3+PE

N/A N/A

N/A

N/A

Table 6