Technical remarks, Internal connections of the electrical heating, 3 ac 1 ac – Alliance Laundry Systems HF150 User Manual

Page 39

Advertising
background image

6

Label 15

Label 16

39

Internal connections of the electrical heating

NOTE:

Other executions are available as options.

3 AC

1 AC

Technical remarks

Heating

3x230V

R5

3x400V

R5

4,2kw

3x1,4kw

See Label 15

LC1D0901

See Label 16

LC1D0901

6kw

3x2kw

See Label 15

LC1D0901

See Label 16

LC1D0901

9kw

3x3kw

See Label 15

LC1D1810

See Label 16

LC1D0901

12kw

3x4kw

--------

--------

See Label 15

LC1D0901

12kw

3x2kw

3x2kw

See Label 15

See Label 15

LC1D1810

LC1D1810

See Label 16

LC1D1810

15kw

3x2kw

3x3kw

See Label 15

See Label 15

LC1D1810

LC1D1810

See Label 16

LC1D1810

18kw

3x3kw

3x3kw

See Label 15

See Label 15

LC1D1810

LC1D1810

See Label 16

LC1D1810

21kw

3x3kw

3x4kw

--------

--------

See Label 16

See Label 15

LC1D1810

LC1D1810

24kw

3x4kw

3x4kw

--------

--------

See Label 15

See Label 15

LC1D1810

LC1D1810

Heating

R5

3kw

LC1D0901

B = Black

Br = Brown

Gy = Grey

Bu = Blue

R = Red

W = White

Table 8

Table 9

"Delta" configuration

"WYE" configuration

Advertising