Steam connection, Warning – Alliance Laundry Systems HF150 User Manual

Page 38

Advertising
background image

5

2

3

4

5

3

1

6

7

7

7

38

Steam connection

Machines with steam heating must have a steam valve between the steam

installation and the machine.

WARNING

Never touch internal or external steam pipes, connections,

or components. These surfaces can be extremely hot and

will cause severe burns. The steam must be turned off and

the pipe, connections, and components allowed to cool

before the pipe can be touched.

Steam Supply Information

MODEL

Steam inlet

connection, inch

Number of

steam inlets

Recommended

pressure, bar

Recommended

pressure, psi

Maximum

pressure, bar

Maximum

pressure, psi

For the HF150, IHF150, IHF033, CHF150, CHF033

3/8

1

2.0 - 5.5 30 - 80 5.5

80

For the HF185, IHF185, IHF045, CHF185, CHF045

3/8

1

2.0 - 5.5 30 - 80 5.5

80

For the HF234, IHF234, IHF055, CHF234, CHF055

1/2

1

2.0 - 5.5 30 - 80 5.5

80

For the HF304, IHF304, IHF075, CHF304, CHF075

1/2

1

2.0 - 5.5 30 - 80 5.5

80

With direct steam injection into the machine (See Table 7)

1. Steam pipe
2. Steam cut-off valve
3. Pipe coupling
4. Steam filter
5. Magnetic steam valve
6. Curve MF
7. Steam hose with appropriate pipe coupling

Table 7