Model g004 flow meter, 1/8" npt, Not to scale 2.26 – Max Machinery G240 Gear Flow Meter User Manual

Page 15: Typical pressure drop

Advertising
background image

Max Machinery, Inc. G Series User Manual © Copyright 2013

Rev. 001Q4

1/8" NPT

1/8" NPT

EX-PROOF HOUSING

TOP VIEW

not to scale

2.26”

(57mm)

2.26”

(57mm)

0.65”

(17mm)

1.93”

(49mm)

1/8” NPT

3.70”

(94mm)

1.75”

(45mm)

1.75”

(45mm)

1/2”

NPT

4.09”

(104mm)

2.26”

(57mm)

1/8” NPT

mounting holes

1/4” - 20NC

(4) places

2.6”

(66mm)

2.75”

(70mm)

MODEL G004 WITH INDUSTRIAL

HOUSING TRANSMITTER

MODEL G004 WITH EX-PROOF

HOUSING TRANSMITTER

BOTTOM VIEW

1.5”

(38mm)

Flow Rate (liters/min)

Pr

es

sur

e Dr

op (p

si)

120

140

20

40

60

100

TYPICAL PRESSURE DROP

Intermittent Duty Area

Expected Failure Area

Continuous Duty Area

80

3

0 cP

100 cP

1000

cP

10,

00

0 c

P

8 bar

6 bar

4 bar

— —

2 bar

2 cP

0.001

0.01

0.1

1

10

Model G004 Flow Meter

Advertising
This manual is related to the following products: