Meter Specifications

Model

G004 G015 G045 G105 G240

1

Maximum flow rate

Liters/min:

4

15

45

105

240

Gal/min:

1

4

11.9

28

64

Maximum pressure (psi)

|-----------------------425 bar (6000 psi)-----------------------|

see below

2

Maximum temperature

--------------------- 2 part: 225°C (435°F) --------------------

3

Recommended filtration

10 micron

15 micron

20 micron

20 micron

30 micron

Displacement (cc/rev)

1.8

4.2

13.5

38

133

Weight (kg)

1.2

1.8

3.7

7.7

21

Typical k-factor (pulses/cc)

500

200 70

25

7

NPT Port size

1/8”

3/8”

1/2”

3/4”

1” to 280 bar (4000 psi)

SAE Port Size

#4

#6

#8

#10

#16 to 425 bar (6000psi)

1

For viscosities of 100 cps or more, derate per pressure drop curves for higher viscosities.

2

Standard transmitter capable to 90°C (195°F)

3

Some materials may have different filter requirements, consult factory.