Transmitter specifications – Max Machinery G240 Gear Flow Meter User Manual

Page 7

Advertising
background image

Max Machinery, Inc. G Series User Manual © Copyright 2013

Rev. 001Q4

Transmitter Specifications

Supply Voltage & Current

Frequency output

5-26 Vdc @ 30 mA typical

Analog output

12Vdc @ 90 mA typical

24Vdc @ 45 mA typical

Analog Resolution

Adjustable without recalibration to any range of

+/- 20mA - Models ending in “A1” and “B1”

+/- 10 Vdc - Models ending in “C1” and “D1”)

FREQUENCY MODEL SPECIFICATIONS

Output (5.0 Volt Supply)

No Load 0.00 / 4.80 Volts

2.5K Load to Common 0.00 / 4.60 Volts

2.5K Load to +5 Volts 0.25 / 4.80 Volts


Short Circuit Current (1)

45 mA

Output Impedance

100

Rise/Fall Time

0.2

μ Sec

Output Update Rate(2)

1 ms

Min/Max Frequency

0-60 kHz

Resolution

1 - 1000 pulses/rev

Ambient Temperature Range

Transmitter (Storage) –40ºC to 85ºC (–40ºF to 185ºF)

Transmitter (Operation) (3) –40ºC to 80ºC (–40ºF to 175ºF)

Maximum Temp, Process Fluid

(Standard Model)

90ºC (195°F)

(20ºC Ambient, 5V supply)

(High Temp Model)

155ºC (310°F)

(Ultra High Temp Model) 225ºC (435°F)

Anti-dither Range Default

50% Revolution of Meter for unidirectional (software selectable

from 1 - 100% of 1 revolution). 2% for bi-directional meters

Signal Filtering

Software selectable from 1ms to 250ms time constant

(1) Continuous Short Circuit is not recommended. The output current should not exceed 10 mA
(2) Events are seen as output transitions 1 ms after they occur
(3) Temperature of metered fluid will affect transmitter temperature, see graph

Advertising
This manual is related to the following products: