Do’s & don’ts – Max Machinery G240 Gear Flow Meter User Manual

Page 9

Advertising
background image

Max Machinery, Inc. G Series User Manual © Copyright 2013

Rev. 001Q4

DO:

Install bypass plumbing around the flow meter. This is

useful during start up for removing dirt and air from

the plumbing or when measuring fluid that may freeze

inside the line and need to be remelted before it can

pass through the meter. It also allows removing the

flow

meter for service without disabling the system.

DO:

Install the meter on its side.

DO:

Be very careful to keep parts clean during installation

or teardown. A little dirt can look like a truckload

compared to the 10 to 30 micron filtration requirement

for G-Series Meters.

DO:

Clean the filter on a regular basis.

DON’T:

Run water or aqueous solutions not approved by Max

through your flow meter because of internal galling.

DON’T:

Steam clean the meter (bypass or remove the meter if

necessary).
DON’T:

Blow down the meter with compressed air or gas

because it may over-speed and damage the meter.

DON’T:

Remove the Transmitter from the flow meter body.

The transmitter is phased to the meter and a

measurement error will result. Re-calibration will be

necessary; see the transmitter interface software

manual.
DON’T:

Disassemble the flow meter. These are precision

devices which require special tools and techniques.

DON’T:

Turn on the pump in a system filled with material that

is solid at room temperature. Wait until the material

is completely melted and use the flow meter bypass

valve during start up.

DON’T:

Apply excessive differential pressure across the flow

meter as it will cause internal failure (see the pressure

drop curves for safe area operation).

DON’T:

Over pressurize the meter. Consult specification table

for maximum pressure.

DON’T:

Exceed the maximum flow rates for the material

viscosity.
DON’T:

Allow materials which solidify in air to set up in the

flow meter. These may be impossible to remove. If

the meter needs to be removed for repair and cannot

be completely cleaned. Plug the inlet and outlet ports

at once.