Corrected Volume Flow Computation:

Temperature Transmitter

Standard Volume Flow = volume flow • (1 - Therm.Exp.Coef. • (Tf-Tref))

2

Density Transmitter
Standard Volume Flow = volume flow • density

reference density

Mass Flow Computation:

Mass Flow = volume flow • density