14

6. Remove dust cap. Attach can by screwing it to the inlet port. Refer to directions

on the can. Observe the sight glass below the inlet port to ensure the can fully
empties into the machine. Leave can on during service.

7. Connect the CarbonClean 1000 battery terminals to the car’s battery. The power

and ready LEDs should be illuminated.

8. Set the pressure on the CarbonClean 1000 by turning the pressure regulator

clockwise slowly until the

MACHINE PRESSURE GAUGE

reads 5-10 psi below the

pressure noted in step 4.

CAUTION: Refer to application guide for vehicle specific instructions.

9. Close the fuel pump ball valve on the manifold assembly to disable the vehicle’s

fuel supply. The engine is now running on the fuel system treatment. Allow the
engine to run until the alarm sounds.

10. When the alarm sounds and the amber Service Complete LED is illuminated the

treatment is complete. Shut off the engine. Disconnect the unit’s battery clips.

CAUTION: Relieve pressure in the fuel line before disconnecting adapters.

11. The pressure can be relieved by doing the following. Turn air pressure regulator

counter-clockwise until the machine pressure gauge reads zero. Press and hold
the flow test button on the back of the CarbonClean 1000. This will lower the
pressure by purging the excess fluid into the flow test bottle mounted on the back
of the machine.

NOTE: Use only approved
chemicals
Use of non approved chemicals
can be a serious fire/explosion
hazard
Do not leave machine
unattended during service.