Warning, Clearance to combustibles, Sa mp le – Detroit Radiant Products Company DX3 Series User Manual

Page 4: Dx3 series, Installer, F/n: lltb004, Radiant tube(s), Input btu/h, For use with, Avoid equipment failure

Advertising
background image

4

HL-40-125N(-3)

Data on this label is for the model shown on this label. If your heater has been converted,
this information is not accurate. Please contact the factory for assistance.

BURNER COMPONENTS:

For parts replacement information, contact factory at 586-756-0950 or visit www.drp-co.com/parts.

Serial No.: 0804XXXXXXXXXX 0001

Gas Valve:
Circuit Board:
Wire Harness:
N.O. Switch:
N.O. VL Orifice:
N.C. Switch:
N.C. VL Orifice:
Diff Switch:
Diff VL Orifice:
Igniter:
Burner:
16” Tube:
Ind. Lights:

Diag. Light:
Term. Block:
Transformer:
Fan:
Alt. Fan:
Alt. Fan Usage:
Relay:
Filter:
24 Volt In:
120 Volt In:
Gas In:
Extra VL Orifice:

Production Code:
Version:

Stock:

Add-On:

Internal Use Only:

HEATER

TYPE:

Electric:
Tag:

Special 1:
Special 2:

Gas:
Air:

C1

C1

C2 C3

None

N/A

HL3-125
7.08

36G54-224-N
35-66
3 PCS Harness
None
None
None
None
IS22010051F5166
Grey (+ / -)
Norton
Mid
4” Gen.
Yellow - 24V

(Specify TP-#’s)

840A
851B
3252
N/A

N/A

264E

50
201B
380
828

On Circuit Board
None
40 VA
Fasco Lg.
50Hz - 120V
When Specified
Picker x2
None
3 T-plug
6’ Blk. Cord
7/8” FC
None

N/A
826
55A
55B

1325
N/A
832
333
83

19

1 5/16”

TP-204#
TP-44#

19

1 7/16”

LLWT038
None

19

1 5/16”

17
1 7/16”

Orifice Type:

®

DETROIT RADIANT PRODUCTS COMPANY

21400 HOOVER ROAD - WARREN, MI

RE-VERBER-RAY INFRA-RED RADIANT TUBE HEATER

FOR OUTDOOR USE AND INDOOR (Non-Residential) INSTALLATION ONLY.
Class IIIA Permanent Label

(586) 756-0950

- www.drp-co.com

Volts AC:

AMPS - Starting:

AMPS - Running:

Combustion Chamber:

120V - 60Hz

4.8

1.1

4” Black Coated Aluminized

For stainless steel upgrades: The combustion tube is 409 Series stainless steel.

DESIGN COMPLIES WITH:

ANSI Z83.20b-2004-GAS FIRED LOW INTENSITY INFRA-RED HTR.

Manifold Pressure:

Maximum Inlet Pressure:

Minimum Inlet Pressure:

3.5 in.

14 in.

5.0 in.

W.C.P.

W.C.P.

W.C.P.

Serial No.: 0807XXXXXXXXXX 0001

MODEL NO.

HL-40-125N(-3)

Heater Type

Minimum Mounting Angle:

Maximum Mounting Angle:

C1

0

45

DEGREES

DEGREES

INPUT BTU/H

125,000 / 95,000

FOR USE WITH

Natural Gas

1.0

Safety • Safety Labels and Locations • Clearance to Combustibles

Clearance to combustibles is defined as the minimum distance that must exist between the tube surface,
or reflector, and any combustible items (see Figure 1.1). It also pertains to the distance that must be
maintained from moving objects around the tube heater. When installing the tube heater system, clearances
to combustibles for the model tube heater and configuration must be maintained. Refer to Chart 1.1 to
determine the required distances for your model.

DX3

Series

WARNING

!

Placement of explosive objects, flammable objects, liquids and vapors close to
the heater may result in explosion, fire, property damage, serious injury or death.
Do not store or use explosive objects, liquids or vapor in the vicinity of the heater.

AVOID EQUIPMENT FAILURE

THIS 10 FT. TUBE IS THE

COMBUSTION CHAMBER.

THIS TUBE MUST BE THE FIRST TUBE

FOLLOWING THE BURNER CONTROL BOX.

!

INSTALLER

The combustion chamber utilizes either 409

stainless, titanium alloy or aluminized steel -

depending on the model number of your heater.

Rotate the tube’s welded seam to bottom.

Consult the manual(s) for further details.

F/N: LLTB004

(orange)

(150,000 - 200,000 Btu/h models only)

Controls Compartment

F/N: LLTB026

F/N: LLTB024L

Fan Compartment

16” Burner Tube

Combustion Chamber

F/N: LLTB025R

F/N: LL01 - Clearance Safety Tag

(Affix adjacent to heater’s thermostat)

SERVICE ACCESS PANEL

IGNITER & FLAME SENSE COMPARTMENT

1. Turn off gas & electricity.

2. Remove cover by lifting top

cover upward and outward.

CAUTION:

HOT SURFACE.

KEEP COVER IN PLACE. REMOVE FOR SERVICE ONLY.

SERVICE ACCESS PANEL

SERVICE ACCESS PANEL

Radiant Tube(s)

Clearance to Combustibles

DX

DX3

SA

MP

LE

DX

SA

MP

LE

®

DETROIT RADIANT PRODUCTS COMPANY

21400 HOOVER ROAD - WARREN, MI

RE-VERBER-RAY INFRA-RED RADIANT TUBE HEATER

FOR INDOOR (Non-Residential) INSTALLATION ONLY.
Class IIIA Permanent Label

(586) 756-0950

- www.drp-co.com

Volts AC:

AMPS - Starting:

AMPS - Running:

Combustion Chamber:

120VAC - 60Hz

1.7

1.1

4” Black Coated Aluminized

DESIGN COMPLIES WITH:

ANSI Z83.20b-2004-GAS FIRED LOW INTENSITY INFRA-RED HTR.

Manifold Pressure:

Maximum Inlet Pressure:

Minimum Inlet Pressure:

3.5 in.

14 in.

5.0 in.

Inches W.C.P.

Inches W.C.P.

Inches W.C.P.

Serial No.: 1208XXXXXXXXXX 0001

MODEL NO.

DET-40-125N(-3)

Heater Type

Minimum Mounting Angle:

Maximum Mounting Angle:

C1

0

45

DEGREES

DEGREES

INPUT BTU/H

125,000 / 95,000

FOR USE WITH

Natural Gas

SERVICE ACCESS PANEL

IGNITER & FLAME SENSE COMPARTMENT


1.
Disconnect gas & electricity.

2. Remove cover by lifting top

cover upward and outward.

CAUTION: HOT SURFACE.

KEEP COVER IN PLACE. REMOVE FOR SERVICE ONLY.

HL3

DX3

Burner Control Box Component Label

(located inside the center compartment lid)

Rating